A compact and stable eddy covariance set-up for methane measurements using off-axis integrated cavity output spectroscopy

76Citations
Citations of this article
136Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A Fast Methane Analyzer (FMA) is assessed for its applicability in a closed path eddy covariance field set-up in a peat meadow. The FMA uses off-axis integrated cavity output spectroscopy combined with a highly specific narrow band laser for the detection of CH4 and strongly reflective mirrors to obtain a laser path length of 2-20 × 103 m. Statistical testing and a calibration experiment showed high precision (7.8 × 10-3 ppb) and accuracy (<0.30%) of the instrument, while no drift was observed. The instrument response time was determined to be 0.10 s. In the field set-up, the FMA is attached to a scroll pump and combined with a 3-axis ultrasonic anemometer and an open path infrared gas analyzer for measurements of carbon dioxide and water vapour. The power-spectra and co-spectra of the instruments were satisfactory for 10Hz sampling rates. Due to erroneous measurements, spikes and periods of low turbulence the data series consisted for 26% of gaps. Observed CH4 fluxes consisted mainly of emission, showed a diurnal cycle, but were rather variable over. The average CH4 emission was 29.7nmol m-2s-1, while the typical maximum CH4 emission was approximately 80.0 nmol m-2s-1 and the typical minimum flux was approximately 0.0 nmol m-2s-1. The correspondence of the measurements with flux chamber measurements in the footprint was good and the observed CH4 emission rates were comparable with eddy covariance CH4 measurements in other peat areas. Additionally, three measurement techniques with lower sampling frequencies were simulated, which might give the possibility to measure CH4 fluxes without an external pump and save energy. Disjunct eddy covariance appeared to be the most reliable substitute for 10 Hz eddy covariance, while relaxed eddy accumulation gave reliable estimates of the fluxes over periods in the order of days or weeks.

References Powered by Scopus

Spectral characteristics of surface‐layer turbulence

2330Citations
N/AReaders
Get full text

Statistics of Atomic Frequency Standards

2178Citations
N/AReaders
Get full text

Estimates of the Annual Net Carbon and Water Exchange of Forests: The EUROFLUX Methodology

1652Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The seasonal cycle of satellite chlorophyll fluorescence observations and its relationship to vegetation phenology and ecosystem atmosphere carbon exchange

312Citations
N/AReaders
Get full text

Measurements necessary for assessing the net ecosystem carbon budget of croplands

247Citations
N/AReaders
Get full text

Accuracy and precision of laser spectrometers for trace gas sensing in the presence of optical fringes and atmospheric turbulence

180Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Hendriks, D. M. D., Dolman, A. J., Van Der Molen, M. K., & Van Huissteden, J. (2008). A compact and stable eddy covariance set-up for methane measurements using off-axis integrated cavity output spectroscopy. Atmospheric Chemistry and Physics, 8(2), 431–443. https://doi.org/10.5194/acp-8-431-2008

Readers over time

‘09‘10‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘2509182736

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 51

46%

Researcher 42

38%

Professor / Associate Prof. 15

13%

Lecturer / Post doc 4

4%

Readers' Discipline

Tooltip

Environmental Science 52

51%

Earth and Planetary Sciences 23

23%

Agricultural and Biological Sciences 16

16%

Physics and Astronomy 10

10%

Save time finding and organizing research with Mendeley

Sign up for free
0