Laboratory evaluation of the effect of nitric acid uptake on frost point hygrometer performance

8Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Chilled mirror hygrometers (CMH) are widely used to measure water vapour in the troposphere and lower stratosphere from balloon-borne sondes. Systematic discrepancies among in situ water vapour instruments have been observed at low water vapour mixing ratios (<5 ppm) in the upper troposphere and lower stratosphere (UT/LS). Understanding the source of the measurement discrepancies is important for a more accurate and reliable determination of water vapour abundance in this region. We have conducted a laboratory study to investigate the potential interference of gas-phase nitric acid (HNO 3) with the measurement of frost point temperature, and consequently the water vapour mixing ratio, determined by CMH under conditions representative of operation in the UT/LS. No detectable interference in the measured frost point temperature was found for HNO 3 mixing ratios of up to 4 ppb for exposure times up to 150 min. HNO 3 was observed to co-condense on the mirror frost, with he adsorbed mass increasing linearly with time at constant exposure levels. Over the duration of a typical balloon sonde ascent (90-120 min), the maximum accumulated HNO 3 amounts were comparable to monolayer coverage of the geometric mirror surface area, which corresponds to only a small fraction of the actual frost layer surface area. This small amount of co-condensed HNO 3 is consistent with the observed lack of HNO 3 interference in the frost point measurement because the CMH utilizes significant reductions (>10%) in surface reflectivity by the condensate to determine H 2O. © 2011 Author(s).

References Powered by Scopus

Water vapor feedback and global warming

995Citations
N/AReaders
Get full text

Contributions of stratospheric water vapor to decadal changes in the rate of global warming

974Citations
N/AReaders
Get full text

An assessment of climate feedbacks in coupled ocean-atmosphere models

797Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Particle backscatter and relative humidity measured across cirrus clouds and comparison with microphysical cirrus modelling

47Citations
N/AReaders
Get full text

An update on the uncertainties of water vapor measurements using cryogenic frost point hygrometers

46Citations
N/AReaders
Get full text

Evaluation of UT/LS hygrometer accuracy by intercomparison during the NASA MACPEX mission

41Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Thornberry, T., Gierczak, T., Gao, R. S., Vömel, H., Watts, L. A., Burkholder, J. B., & Fahey, D. W. (2011). Laboratory evaluation of the effect of nitric acid uptake on frost point hygrometer performance. Atmospheric Measurement Techniques, 4(2), 289–296. https://doi.org/10.5194/amt-4-289-2011

Readers' Seniority

Tooltip

Researcher 2

40%

Professor / Associate Prof. 1

20%

Lecturer / Post doc 1

20%

PhD / Post grad / Masters / Doc 1

20%

Readers' Discipline

Tooltip

Environmental Science 3

60%

Physics and Astronomy 1

20%

Chemistry 1

20%

Save time finding and organizing research with Mendeley