Performance evaluation of a high-resolution parallel-plate differential mobility analyzer

30Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

Abstract

A high-resolution differential mobility analyzer (DMA), specially designed for (i) the measurement of ion mobility spectra, and (ii) the generation of a continuous stream of monomobile ions, has been developed and tested. The apparatus consists of two parallel-plate electrodes between which an electric field is applied. The test ion stream flows into the instrument through a narrow rectangular slit made in one of the electrodes, and migrates toward the other electrode driven by the applied field, while being transported by a stream of clean air which flows parallel to the plates at Reynolds number between 2 x1o4 and 9x 104 in laminar flow conditions. The collector electrode contains also a narrow slit through which ions of the desired mobility are withdrawn out of DMA. The classified ion current is measured with a highsensitivity electrometer having a noise level around 0.1 fA. The theory behind the DMA operation is first discussed, focusing on the special case of parallel-plate geometry. Some generic results showing the stability and repeatability of the measurements and the resolving power of the instrument are presented next. The last part of the paper deals with the application of the apparatus to the study of the effect of humidity and aging time on the mobility spectra of air ions generated by a low-activity 241Am source.

References Powered by Scopus

Electrospray ionization for mass spectrometry of large biomolecules

6767Citations
N/AReaders
Get full text

Aerosol classification by electric mobility: apparatus, theory, and applications

1172Citations
N/AReaders
Get full text

Ion mobility measurements and their applications to clusters and biomolecules

711Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Lipid analysis and lipidomics by structurally selective ion mobility-mass spectrometry

200Citations
N/AReaders
Get full text

State of ion mobility spectrometry and applications in agriculture: A review

39Citations
N/AReaders
Get full text

Characterization of a Herrmann-type high-resolution differential mobility analyzer

36Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Santos, J. P., Hontañón, E., Ramiro, E., & Alonso, M. (2009). Performance evaluation of a high-resolution parallel-plate differential mobility analyzer. Atmospheric Chemistry and Physics, 9(7), 2419–2429. https://doi.org/10.5194/acp-9-2419-2009

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 14

54%

Researcher 10

38%

Professor / Associate Prof. 2

8%

Readers' Discipline

Tooltip

Engineering 10

38%

Environmental Science 6

23%

Chemistry 5

19%

Physics and Astronomy 5

19%

Save time finding and organizing research with Mendeley

Sign up for free