Quality assessment of ozone total column amounts as monitored by ground-based solar absorption spectrometry in the near infrared (> 3000 cm-1)

11Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

This study examines the possibility of ground-based remote-sensing ozone total column amounts (OTC) from spectral signatures at 3040 and 4030 cm-1. These spectral regions are routinely measured by the NDACC (Network for the Detection of Atmospheric Composition Change) ground-based FTIR (Fourier transform infraRed) experiments. In addition, they are potentially detectable by the TCCON (Total Carbon Column Observing Network) FTIR instruments. The ozone retrieval strategy presented here estimates the OTC from NDACC FTIR high-resolution spectra with a theoretical precision of about 2 and 5% in the 3040 and 4030 cm-1 regions, respectively. Empirically, these OTC products are validated by inter-comparison to FTIR OTC reference retrievals in the 1000 cm-1 spectral region (standard reference for NDACC ozone products), using an 8-year FTIR time series (2005-2012) taken at the subtropical ozone supersite of the Izaña Atmospheric Observatory (Tenerife, Spain). Associated with the weaker ozone signatures at the higher wave number regions, the 3040 and 4030 cm-1 retrievals show lower vertical sensitivity than the 1000 cm-1 retrievals. Nevertheless, we observe that the rather consistent variations are detected: the variances of the 3040 cm-1 and the 4030 cm-1 retrievals agree within 90 and 75%, respectively, with the variance of the 1000 cm-1 standard retrieval. Furthermore, all three retrievals show very similar annual cycles. However, we observe a large systematic difference of about 7% between the OTC obtained at 1000 and 3040 cm-1, indicating a significant inconsistency between the spectroscopic ozone parameters (HITRAN, 2012) of both regions. Between the 1000 cm and the 4030 cm-1 retrieval the systematic difference is only 2-3%. Finally, the long-term stability of the OTC retrievals has also been examined, observing that both near-infrared retrievals can monitor the long-term OTC evolution, consistent with the 1000 cm-1 reference data. These findings demonstrate that recording the solar absorption spectra in the 3000 cm-1 spectral region at high spectral resolution (about 0.005 cm-1) might be useful for TCCON sites. Hence, both NDACC and TCCON ground-based FTIR experiments might contribute to global ozone databases.

References Powered by Scopus

The HITRAN 2008 molecular spectroscopic database

3277Citations
N/AReaders
Get full text

The HITRAN2012 molecular spectroscopic database

3095Citations
N/AReaders
Get full text

The HITRAN 2004 molecular spectroscopic database

2755Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Ground-based spectroscopic measurements of atmospheric gas composition near Saint Petersburg Russia

51Citations
N/AReaders
Get full text

Validation of ozone intensities at 10 µm with THz spectrometry

18Citations
N/AReaders
Get full text

Ozone intensities in the rotational bands

18Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

García, O. E., Schneider, M., Hase, F., Blumenstock, T., Sepúlveda, E., & González, Y. (2014). Quality assessment of ozone total column amounts as monitored by ground-based solar absorption spectrometry in the near infrared (> 3000 cm-1). Atmospheric Measurement Techniques, 7(9), 3071–3084. https://doi.org/10.5194/amt-7-3071-2014

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

64%

Researcher 4

36%

Readers' Discipline

Tooltip

Environmental Science 5

50%

Earth and Planetary Sciences 4

40%

Engineering 1

10%

Save time finding and organizing research with Mendeley

Sign up for free