Seismic behavior of two exterior beam-column connections made of normal-strength concrete developed for precast construction

117Citations
Citations of this article
110Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The lack of in-depth understanding of the seismic behavior and ductility of precast concrete structures makes it difficult to reach to ductility demand which could be exhibited during an earthquake. The limitations are mainly related to the beam-to-column connections as the main load transfer paths. Two distinct exterior beam-column connections made of normal-strength concrete are investigated experimentally. Both dry and wet type installment techniques are used in the industrial type joints while the residential type joints are wet connections. The specimens are subjected cyclic displacement reversals in order to obtain information on strength, stiffness and ductility characteristics of the connection details. The preliminary design of the joints has been updated during the tests based on the damages observed, thus a set of improved specimens have also been built and tested, and a relatively better performance is obtained expectedly. The industrial and residential types of connections showed stable load-displacement cycles with high energy dissipation up to structural drift of 2%, though a significant level of pinching and deterioration of the critical section have occurred at around 3% drift level. The tested specimens have been numerically modeled to calibrate the analytical tools, and a satisfactory approximation has been obtained between experimental and numerical results.

References Powered by Scopus

Theoretical stress-strain model for confined concrete

7605Citations
N/AReaders
Get full text

Localization issues in force-based frame elements

338Citations
N/AReaders
Get full text

A new ductile moment-resisting connection for precast concrete frames in seismic regions: An experimental investigation

266Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Design for Manufacture and Assembly-oriented parametric design of prefabricated buildings

225Citations
N/AReaders
Get full text

Seismic experimental study on a precast concrete beam-column connection with grout sleeves

197Citations
N/AReaders
Get full text

Development and testing of hybrid precast concrete beam-to-column connections under cyclic loading

144Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Yuksel, E., Karadogan, H. F., Bal, I. E., Ilki, A., Bal, A., & Inci, P. (2015). Seismic behavior of two exterior beam-column connections made of normal-strength concrete developed for precast construction. Engineering Structures, 99, 157–172. https://doi.org/10.1016/j.engstruct.2015.04.044

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 43

68%

Researcher 8

13%

Professor / Associate Prof. 6

10%

Lecturer / Post doc 6

10%

Readers' Discipline

Tooltip

Engineering 61

91%

Design 2

3%

Agricultural and Biological Sciences 2

3%

Environmental Science 2

3%

Save time finding and organizing research with Mendeley

Sign up for free