Performance of a thick 250 μm silicon carbide detector: stability and energy resolution

5Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Silicon carbide detectors represent an alternative to diamond detectors for fast neutron detection in harsh environments, especially fusion plasmas. Previous studies on thin prototypes (either 10 μm or 100 μm thick) suggested that thicker active volumes might be better suited for spectroscopy measurements, due to the higher chance of retaining the neutron interaction products inside the active volume. Therefore, in this work two 250 μm SiC prototypes are tested with alpha particles following the same process conducted in the past for thinner prototypes. A stable detection is demonstrated, along an energy resolution that, if projected to DT neutrons, could become the lowest achieved so far with a SiC detector (1.3%). Some difficulties in reaching a full depletion are highlighted, as long as perspectives of a partial polarization operation of the detectors.

References Powered by Scopus

Compound semiconductor radiation detectors

529Citations
N/AReaders
Get full text

Development of a silicon carbide radiation detector

158Citations
N/AReaders
Get full text

Study of Silicon Carbide for X-Ray Detection and Spectroscopy

135Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Partially depleted operation of 250 μm-thick silicon carbide neutron detectors

3Citations
N/AReaders
Get full text

Operation of a 250μm-thick SiC detector with DT neutrons at high temperatures

1Citations
N/AReaders
Get full text

250 μm Thick Detectors for Neutron Detection: Design, Electrical Characteristics, and Detector Performances

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kushoro, M. H., Rebai, M., La Via, F., Meli, A., Meda, L., Parisi, M., … Tardocchi, M. (2023). Performance of a thick 250 μm silicon carbide detector: stability and energy resolution. Journal of Instrumentation, 18(3). https://doi.org/10.1088/1748-0221/18/03/C03007

Readers' Seniority

Tooltip

Researcher 3

60%

Professor / Associate Prof. 1

20%

PhD / Post grad / Masters / Doc 1

20%

Readers' Discipline

Tooltip

Materials Science 2

40%

Agricultural and Biological Sciences 1

20%

Computer Science 1

20%

Chemistry 1

20%

Save time finding and organizing research with Mendeley

Sign up for free