Study on dehumidification performance of a multi-stage internal cooling solid desiccant adsorption packed bed

6Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

Abstract

In this paper, the solid desiccant adsorption packed bed with a three-stage internal cooling (ICSPB) has been proposed to improve the dehumidification efficiency and make a comparison with that of non-internal cooling. To investigate the performance of the ICSPB, the dehumidification capacity, dehumidification efficiency, water content of solid desiccant, moisture ratio of solid desiccant, temperature of solid desiccant and inlet and outlet air temperature difference were discussed in different conditions of inlet air and supplying water temperature. It was found that the dehumidification performance of the bed with internal cooling could be improved greatly in the low temperature and low humidity conditions, while in the high temperature and humid, the improvement was not obvious. With internal cooling, the dehumidification efficiency and the water content of the solid desiccant could be improved 59.69% and 110.7%, respectively, and the temperature of solid desiccant could be reduced 2.2◦C when the ICSPB operated at the inlet air temperature of 20◦C, inlet humidity of 55%, and water temperature of 14◦C. Moreover, the dehumidification performance at each stage of ICSPB was studied. It was found that, the first stage played the most important role in the dehumidification process. In addition, the calculation models that can be used to predict the moisture ratio and the temperature of solid desiccant were established on the test results.

References Powered by Scopus

Performance comparisons of desiccant wheels for air dehumidification and enthalpy recovery

239Citations
N/AReaders
Get full text

Moisture transport in silica gel packed beds-I.Theoretical study

208Citations
N/AReaders
Get full text

Solid desiccant air conditioning - A state of the art review

202Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Optimization of parameters for air dehumidification systems including multilayer fixed-bed binder-free desiccant dehumidifier

25Citations
N/AReaders
Get full text

Effect of climatic conditions on the performance of a multistage dynamic dehumidifier test rig

8Citations
N/AReaders
Get full text

Novel MOF-303/G coated wire-finned heat exchanger for dehumidification applications–Experimental investigation

4Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Yang, W., Ren, J., Lin, Z., Wang, Z., & Zhao, X. (2018). Study on dehumidification performance of a multi-stage internal cooling solid desiccant adsorption packed bed. Energies, 11(11). https://doi.org/10.3390/en11113038

Readers over time

‘18‘19‘20‘21‘22‘23‘2402468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 9

64%

Researcher 4

29%

Lecturer / Post doc 1

7%

Readers' Discipline

Tooltip

Engineering 10

83%

Chemical Engineering 1

8%

Materials Science 1

8%

Save time finding and organizing research with Mendeley

Sign up for free
0