Technical note: A device to directly measure transpiration from vegetation grown in containers

1Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

Information about evaporation and transpiration fluxes is vital for water budgets, modeling of water flows and climate, as well as for assessing the hydrological impact of land management practices. Under natural conditions, these fluxes are difficult to measure accurately, which results in large measurement inaccuracies. These inaccuracies can be reduced in controlled experiments. We present a device that is especially useful for transpiration studies conducted in large and/or heavy containers where weighing becomes too cumbersome or expensive. With our device we set a water table and control soil moisture of potted small trees by periodically replenishing soil water consumed by the tree, thereby measuring the inflow volume, which represent whole-tree transpiration. The device is made of inexpensive, easily available and durable materials and can be used for in- and outdoor experiments. Data acquisition is fast and easy. The mean measurement error of the device is 4.5% (±3.2% SD) for refill (i.e., transpiration) volumes of 1.5 L or larger. For a transpiring surface of 3 m2, this amount is equal to an accuracy of 0.02 mm. Validation on field data showed that transpiration measured by the device is comparable to transpiration measured by gravimetric changes.

References Powered by Scopus

Evapotranspiration information reporting: I. Factors governing measurement accuracy

813Citations
N/AReaders
Get full text

A review of approaches for evapotranspiration partitioning

623Citations
N/AReaders
Get full text

Evapotranspiration: A process driving mass transport and energy exchange in the soil-plant-atmosphere-climate system

386Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The effect of plant size and branch traits on rainfall interception of 10 temperate tree species

11Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Pflug, S., Voortman, B. R., & Witte, J. P. M. (2020). Technical note: A device to directly measure transpiration from vegetation grown in containers. Water (Switzerland), 12(2). https://doi.org/10.3390/w12020355

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

67%

Researcher 3

25%

Lecturer / Post doc 1

8%

Readers' Discipline

Tooltip

Agricultural and Biological Sciences 6

46%

Environmental Science 4

31%

Engineering 2

15%

Chemical Engineering 1

8%

Article Metrics

Tooltip
Mentions
Blog Mentions: 1

Save time finding and organizing research with Mendeley

Sign up for free