The Use of a New Dedicated Electrocautery Lumen-Apposing Metal Stent for Gallbladder Drainage in Patients with Acute Cholecystitis

5Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

Aims: Lumen-apposing metal stents (LAMSs) in ultrasonography-guided gallbladder drainage (EUS-GBD) have become increasingly important for high-risk surgical patients. Our study aims to evaluate the technical and clinical success, safety, and feasibility of endoscopic ultrasonography-guided gallbladder drainage using a new dedicated LAMS. Methods: This is a retrospective multicenter study that included all consecutive patients not suitable for surgery who were referred to a tertiary center for EUS-GBD using a new dedicated electrocautery LAMS for acute cholecystitis at eight different centers. Results: Our study included 54 patients with a mean age of 76.48 years (standard deviation: 12.6 years). Out of the 54 endoscopic gallbladder drainages performed, 24 (44.4%) were cholecysto-gastrostomy, and 30 (55.4%) were cholecysto-duodenostomy. The technical success of LAMS placement was 100%, and clinical success was achieved in 23 out of 30 patients (76.67%). Adverse events were observed in two patients (5.6%). Patients were discharged after a median of 5 days post-stenting. Conclusions: EUS-GBD represents a valuable option for high-surgical-risk patients with acute cholecystitis. This new dedicated LAMS has demonstrated a high rate of technical and clinical success, along with a high level of safety.

References Powered by Scopus

A lexicon for endoscopic adverse events: report of an ASGE workshop

1779Citations
N/AReaders
Get full text

Tokyo Guidelines 2018: diagnostic criteria and severity grading of acute cholecystitis (with videos)

762Citations
N/AReaders
Get full text

The management of antithrombotic agents for patients undergoing GI endoscopy

532Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Endoscopic Gallbladder Drainage: A Comprehensive Review on Indications, Techniques, and Future Perspectives

5Citations
N/AReaders
Get full text

Indirect comparison of various lumen-apposing metal stents for EUS-guided biliary and gallbladder drainage: a systematic review and meta-analysis

2Citations
N/AReaders
Get full text

Revolutionizing outcomes: endoscopic ultrasound-guided gallbladder drainage using innovative electrocautery enhanced-lumen apposing metal stents for high-risk surgical patients

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Brandaleone, L., Franchellucci, G., Facciorusso, A., Samanta, J., Moon, J. H., Vargas-Madrigal, J., … Mangiavillano, B. (2023). The Use of a New Dedicated Electrocautery Lumen-Apposing Metal Stent for Gallbladder Drainage in Patients with Acute Cholecystitis. Diagnostics, 13(21). https://doi.org/10.3390/diagnostics13213341

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

100%

Readers' Discipline

Tooltip

Economics, Econometrics and Finance 1

50%

Medicine and Dentistry 1

50%

Article Metrics

Tooltip
Mentions
Blog Mentions: 1
News Mentions: 1

Save time finding and organizing research with Mendeley

Sign up for free