This paper presents a moving-magnet type linear actuator designed by using flux concentration type permanent magnet arrangement, which can generate higher magnetic flux density in air-gap. In this construction, detent force which is induced by both slot-effect and end-effect becomes larger due to strong attractive forces. To reduce cogging force we have employed a modular mover structure of two magnetic pole sections connected with a center yoke. The improved motor performance is demonstrated with the prototype machine.
Mendeley helps you to discover research relevant for your work.
CITATION STYLE
Goto, A., Okamoto, T., Ikariga, A., Todaka, T., & Enokizono, M. (2012). A new moving-magnet type linear actuator utilizing flux concentration permanent magnet arrangement. Journal of Electrical Engineering and Technology, 7(3), 342–348. https://doi.org/10.5370/JEET.2012.7.3.342