Abstract

A method is described for establishing an upper bound on the spatial encoding capabilities of coil arrays in parallel MRI. Ultimate intrinsic signal-to-noise ratio (SNR), independent of any particular conductor arrangement, is calculated by expressing arbitrary coil sensitivities in terms of a complete set of basis functions that satisfy Maxwell's equations within the sample and performing parallel imaging reconstructions using these basis functions. The dependence of the ultimate intrinsic SNR on a variety of experimental conditions is explored and a physically intuitive explanation for the observed behavior is provided based on a comparison between the electromagnetic wave-length and the distance between aliasing points. Imaging at high field strength, with correspondingly short wavelength, is shown to offer advantages for parallel imaging beyond those already expected due to the larger available spin polarization. One-dimensional undersampling of k-space yields a steep drop in attainable SNR for more than a 5-fold reduction of scan time, while 2D undersampling permits access to much higher degrees of acceleration. Increased tissue conductivity decreases baseline SNR, but improves parallel imaging performance. A procedure is also provided for generating the optimal coil sensitivity pattern for a given acceleration, which will serve as a useful guide for future coil designs. © 2003 Wiley-Liss, Inc.

Author supplied keywords

References Powered by Scopus

SENSE: Sensitivity encoding for fast MRI

5684Citations
N/AReaders
Get full text

The NMR phased array

1997Citations
N/AReaders
Get full text

Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays

1989Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain FMRI

1144Citations
N/AReaders
Get full text

Multiplexed echo planar imaging for sub-second whole brain fmri and fast diffusion imaging

1016Citations
N/AReaders
Get full text

Pushing spatial and temporal resolution for functional and diffusion MRI in the Human Connectome Project

622Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ohliger, M. A., Grant, A. K., & Sodickson, D. K. (2003). Ultimate Intrinsic Signal-to-Noise Ratio for Parallel MRI: Electromagnetic Field Considerations. Magnetic Resonance in Medicine, 50(5), 1018–1030. https://doi.org/10.1002/mrm.10597

Readers over time

‘09‘10‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘2506121824

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 48

50%

Researcher 33

34%

Professor / Associate Prof. 12

13%

Lecturer / Post doc 3

3%

Readers' Discipline

Tooltip

Engineering 40

48%

Medicine and Dentistry 19

23%

Physics and Astronomy 18

22%

Neuroscience 6

7%

Save time finding and organizing research with Mendeley

Sign up for free
0