Improvement of tidal breathing pattern analysis in children with asthma by on-line automatic data processing

20Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

The time taken to achieve peak tidal expiratory flow as a proportion of total expiratory time (t PTEF/t E) during tidal breathing (TB) is used as a parameter of airway obstruction in children with asthma. Curve selection bias is one of the most important limitations to the method. This study evaluates three curve selection methods, including a computer program, which ondine selects and analyses TB curves (Masterscreen Paediatric; Jaeger, Germany). TB analysis was performed in 26 children (aged 4-7 yrs) with asthma, before and after methacholine provocation and after subsequent bronchodilatation. Levels and stability of TB parameters derived from computer-selected, unselected and unbiased eye-selected curves were compared. t PTEF/t E ratios of the computer-selected curves agreed well with the unbiased eye-selected curves (limits of agreement -4.8 and +5.8%), but were significantly different from the ratios of unselected curves. Computer-derived t PTEF/t E ratios had the highest level of stability: the reliability coefficient of baseline measurements was 0.96 for computer selection, 0.84 for eye selection and 0.87 for no selection (reliability index = 1 at maximal stability). Tidal volume, respiratory rate, inspiratory and expiratory time were also assessed accurately by the computer program. The mean t PTEF/t E ratio (computer selection) dropped after methacholine provocation (from 30±9 to 22±9% at provocative dose at which forced expiratory volume in one second had dropped ≤20% from baseline (FEV1-PD20 level), p<0.001) and was restored after bronchodilatation (30±6%; p<0.001). We conclude that on-line computer analysis is preferable to no selection and to by-eye selection. The use of the program avoids curve selection bias and enhances the applicability of tidal breathing analysis as a measure of airflow obstruction in young children.

References Powered by Scopus

STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

42141Citations
N/AReaders
Get full text

Standardization of spirometry--1987 update. Statement of the American Thoracic Society.

0
2333Citations
N/AReaders
Get full text

Diminished Lung Function as a Predisposing Factor for Wheezing Respiratory Illness in Infants

598Citations
N/AReaders
Get full text

Cited by Powered by Scopus

An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary function testing in preschool children

1018Citations
N/AReaders
Get full text

Tidal breath analysis for infant pulmonary function testing

213Citations
N/AReaders
Get full text

Oscillation mechanics of the respiratory system

158Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Van der Ent, C. K., Brackel, H. J. L., Mulder, P., & Bogaard, J. M. (1996). Improvement of tidal breathing pattern analysis in children with asthma by on-line automatic data processing. European Respiratory Journal, 9(6), 1306–1313. https://doi.org/10.1183/09031936.96.09061306

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

50%

Researcher 6

43%

Professor / Associate Prof. 1

7%

Readers' Discipline

Tooltip

Medicine and Dentistry 7

47%

Engineering 5

33%

Agricultural and Biological Sciences 2

13%

Computer Science 1

7%

Save time finding and organizing research with Mendeley

Sign up for free