Assessment of appropriate SFCL type considering DC fault interruption in full bridge modular multilevel converter HVDC system

16Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The modular multilevel converter (MMC) is the most promising converter topology for implementations of voltage source converter (VSC) high-voltage direct-current (HVDC) grid. Existing research has focused on operational characteristics and improvement of efficiency by optimizing the control. Among various MMC topologies, a full bridge (FB) sub-module (SM) MMC with fault interruption capability has attracted attention because it does not require a dc circuit breaker. However, the most severe faults on dc line, can cause steeply rising fault currents with high peak magnitude, but there is a lack of literature regarding fault current reduction in FB-MMC systems. This problem can be overcome by applying the fault current limiter (FCL) and the superconducting fault current limiters (SFCLs), which have already been developed for the ac grid, have been considered in this paper. We have verified the applicability of two well-known SFCL types i.e., resistive SFCL (R-SFCL) and saturated iron core type SFCL (SIC-SFCL) in FB-MMC grid. Current limiting characteristics and energy dissipation has been according to the location of fault on dc line has been studied. We compared the merits and demerits of the aforementioned SFCLs based on the simulation results. The results indicate, SIC-SFCL to be the most suitable fault current limiter for FB-MMC HVDC system application. © 2001 Elsevier Science. All rights reserved

Figures

References Powered by Scopus

Multilevel converters: An enabling technology for high-poer applications

1104Citations
N/AReaders
Get full text

HVDC circuit breakers: A review identifying future research needs

1014Citations
N/AReaders
Get full text

High-temperature superconductor fault current limiters: Concepts, applications, and development status

489Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Superconducting fault current limiter (SFCL) for a power electronic circuit: Experiment and numerical modelling

32Citations
N/AReaders
Get full text

Review of the fault current limiting approaches for a flexible DC grid based on a half-bridge MMC

26Citations
N/AReaders
Get full text

Design and simulation of resistive type SFCL in multi-area power system for enhancing the transient stability

18Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lee, H. Y., Asif, M., Park, K. H., & Lee, B. W. (2019). Assessment of appropriate SFCL type considering DC fault interruption in full bridge modular multilevel converter HVDC system. Physica C: Superconductivity and Its Applications, 563, 1–6. https://doi.org/10.1016/j.physc.2019.04.006

Readers over time

‘19‘20‘22‘2302468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

75%

Researcher 1

25%

Readers' Discipline

Tooltip

Engineering 4

100%

Save time finding and organizing research with Mendeley

Sign up for free
0