The study aimed to evaluate the effectiveness and safety of long-term use of closed-loop insulin system (CLS) in non-pregnant patients with type 1 diabetes mellitus (T1DM) using systematic review and meta-analysis. A literature search was performed using MEDLINE, EMBASE, and the Cochrane Library. Randomized controlled trials (RCTs) on long-term use (not less than 8 weeks) of CLS in patients with T1DM were selected. Meta-analysis was performed with RevMan V.5.3.5 to compare CLS with controls (continuous subcutaneous insulin infusion with blinded continuous glucose monitoring or unblinded sensor-augmented pump therapy or multiple daily injections or predictive low-glucose suspend system) in adults and children with type 1 diabetes. Research quality evaluation was conducted using the Cochrane risk of bias tool. Eleven RCTs (817 patients) that satisfied the eligibility criteria were included in the meta-analysis. Compared with controls, the CLS group had a favorable effect on the proportion of time with sensor glucose level in 3.9-10 mmol/L (10.32%, 8.70% to 11.95%), above 10 mmol/L (-8.89%, -10.57% to -7.22%), or below 3.9 mmol/L (-1.09%, -1.54% to -0.64%) over 24 hours. The CLS group also had lower glycated hemoglobin levels (-0.30%, -0.41% to -0.19%), and glucose variability, coefficient of variation of glucose, and SD were lower by 1.41 (-2.38 to -0.44, p=0.004) and 6.37 mg/dL (-9.19 mg/dL to -3.55 mg/dL, p<0.00001). There were no significant differences between the CLS and the control group in terms of daily insulin dose, quality of life assessment, and satisfaction with diabetes treatment. CLS is a better solution than control treatment in optimizing blood glucose management in patients with T1DM. CLS could become a common means of treating T1DM in clinical practice.

Cite

CITATION STYLE

APA

Jiao, X., Shen, Y., & Chen, Y. (2022, April 21). Better TIR, HbA1c, and less hypoglycemia in closed-loop insulin system in patients with type 1 diabetes: a meta-analysis. BMJ Open Diabetes Research and Care. BMJ Publishing Group. https://doi.org/10.1136/bmjdrc-2021-002633

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free