BACKGROUND: Although clinical trials have reported favorable outcomes after drug-coated balloon (DCB) therapy for femoro-popliteal lesions, their real-world performance and predictors have not been well evaluated. This study aimed to elucidate 1-year freedom from restenosis and to explore the associated factors after a DCB for femoropopliteal lesions in clinical settings. METHODS AND RESULTS: This multicenter, prospective cohort registered 3165 de novo or restenotic femoropopliteallesions (mean lesion length, 13.5±9.3 cm; chronic total occlusion, 25.9%; severe calcification, 14.6%) that underwent successful DCB (Lutonix [24.2%] and IN.PACT Admiral [75.8%]) treatment between March 2018 and December 2019. Patency was assessed at 12±2 months. The primary outcome measure was 1-year freedom from restenosis and its associated factors. Bailout stenting was performed in 3.5% of patients. The postprocedural slow flow phenomenon was observed in 3.9% of patients. During a median follow-up of 14.2 months, 811 patients experienced restenosis. The Kaplan– Meier estimate of freedom from restenosis was 84.5% at 12 months (79.7% at 14 months). Focal, tandem, diffuse, and occlusive restenosis accounted for 37.4%, 9.8%, 18.9%, and 33.9%, respectively. Freedom from target lesion revascularization was 91.5% at 12 months. Risk factors indepen-dently associated with 1-year restenosis were a history of revascularization, smaller distal reference vessel diameter, severe calcification, chronic total occlusion, low-dose DCB, and residual stenosis. CONCLUSIONS: The 1-year clinical outcomes after DCB use for femoropopliteal lesions in real-world practice was favorable. The additive risk factors were associated with a lower rate of freedom from restenosis.

References Powered by Scopus

This article is free to access.

Get full text
893Citations
232Readers

This article is free to access.

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Soga, Y., Takahara, M., Iida, O., Tomoi, Y., Kawasaki, D., Tanaka, A., … Ando, K. (2023). Vessel Patency and Associated Factors of Drug-Coated Balloon for Femoropopliteal Lesion. Journal of the American Heart Association, 12(1). https://doi.org/10.1161/JAHA.122.025677

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

63%

Researcher 3

38%

Readers' Discipline

Tooltip

Medicine and Dentistry 5

63%

Philosophy 1

13%

Engineering 1

13%

Pharmacology, Toxicology and Pharmaceut... 1

13%

Article Metrics

Tooltip
Mentions
News Mentions: 1

Save time finding and organizing research with Mendeley

Sign up for free