Abstract

Objectives: Thrombin generation assays and activated partial thromboplastin time (aPTT)-based clot waveform analysis (CWA), are some examples of global coagulation assays. Each modality evaluates different aspects of the clot forming process to globally define haemostasis with exclusive measurement parameters. Data on CWA are emerging, but its performance against other haemostatic assays is yet to be ascertained. This study evaluates the correlation between aPTT-based CWA and CAT parameters across a range of INR in warfarin-treated patients. Patients/Methods: A prospective study consisting of patients on warfarin anticoagulation with varying INR levels. CWA and CAT were performed for the study subjects. Results: 54 samples were included covering an INR range from 1.33–6.89, with a mean of 4.31 +/- 1.13. For CAT parameters, endogenous thrombin potential (ETP) and peak thrombin were assessed. Both unadjusted and adjusted (adjusted for final plateau transmittance) aPTT-based CWA were evaluated for parameters min1 (maximum velocity), min2 (maximum acceleration) and max2 (maximum deceleration). Peak thrombin showed significant correlation with all CWA parameters (min1: r = 0.435, P<0.001; min2: r = 0.485, P<0.001; max2: r = 0.578, P<0.001; adjusted min1: r = 0.734, P<0.001, adjusted min2: r = 0.693, P<0.001; adjusted max2: r = 0.751, P<0.001). ETP correlated significantly with all CWA parameters except unadjusted min1 (min1: r = 0.235, P = 0.087; min2: r = 0.326, P = 0.016; max2: r = 0.437, P<0.001; adjusted min1: r = 0.610, P<0.001, adjusted min2: r = 0.563, P<0.001; adjusted max2: r = 0.642, P<0.001). Conclusion: We demonstrated a modest correlation between CAT and CWA parameters. Adjusted CWA improved this correlation. These findings provide additional understanding of CWA and it’s role in the evaluation of global haemostatic function.

References Powered by Scopus

Get full text

This article is free to access.

This article is free to access.

Cited by Powered by Scopus

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Cheong, M. A., Tan, C. W., Wong, W. H., Kong, M. C., See, E., Yeang, S. H., … Ng, H. J. (2022). A correlation of thrombin generation assay and clot waveform analysis in patients on warfarin. Hematology (United Kingdom), 27(1), 337–342. https://doi.org/10.1080/16078454.2022.2043573

Readers over time

‘22‘23‘24‘2500.751.52.253

Readers' Seniority

Tooltip

Professor / Associate Prof. 1

33%

Lecturer / Post doc 1

33%

Researcher 1

33%

Readers' Discipline

Tooltip

Medicine and Dentistry 2

50%

Biochemistry, Genetics and Molecular Bi... 1

25%

Veterinary Science and Veterinary Medic... 1

25%

Article Metrics

Tooltip
Mentions
News Mentions: 1

Save time finding and organizing research with Mendeley

Sign up for free
0