Treatment planning comparison between dynamic wave arc and volumetric modulated arc therapies for prostate-cancer treatment

3Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The aim of this study was to compare the quality of dynamic wave arc (DWA) and coplanar volumetric modulated arc therapy (co-VMAT) plans for the treatment of localized prostate cancer. The planning target volume (PTV)-rectum, a section of the PTV comprising the PTV minus that of the rectum, received 78 Gy in 39 fractions as the mean dose to the PTV-rectum. The DWA and co-VMAT plans were generated for each patient using the RayStation treatment planning system for the Vero4DRT system. The PTV-rectum dose (D95%: the percent dose irradiating 95% of the volume), homogeneity index (HI), conformity index (CI), as well as doses to the bladder wall, rectum wall (V10–70 Gy: the percent volume receiving 10–70 Gy), and bilateral femoral heads of the DWA and co-VMAT plans were compared. The output monitor unit (MU) and delivery time obtained for each set of plans were also investigated. In terms of target coverage, the DWA plans provided an average D95% of 75.5 Gy, which was comparable to the co-VMAT-plan D95% of 75.2 Gy (p < 0.05). The HI was significantly better with the DWA. As for the DWA plans, the bladder-wall volume receiving 10, 20, 30, and 40 Gy (V10–40 Gy) was significantly smaller than that of the co-VMAT plans, and the volume of the rectal wall receiving 10 Gy (V10Gy) was significantly larger than that of the co-VMAT plans. The DWA plans yielded a reduced dose to the bilateral femoral heads compared with the co-VMAT plans (p < 0.05). The values of the CI and MU, and the delivery time exhibited no significant differences between the DWA and co-VMAT plans. The DWA plan is a feasible treatment option for prostate cancer radiotherapy.

References Powered by Scopus

Cited by Powered by Scopus

Get full text

This article is free to access.

This article is free to access.

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Miura, H., Nakao, M., Doi, Y., Ozawa, S., Kenjo, M., & Nagata, Y. (2022). Treatment planning comparison between dynamic wave arc and volumetric modulated arc therapies for prostate-cancer treatment. Medical Dosimetry, 47(1), 48–53. https://doi.org/10.1016/j.meddos.2021.08.001

Save time finding and organizing research with Mendeley

Sign up for free