Technologies for continuous glucose monitoring: Current problems and future promises

222Citations
Citations of this article
379Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Devices for continuous glucose monitoring (CGM) are currently a major focus of research in the area of diabetes management. It is envisioned that such devices will have the ability to alert a diabetes patient (or the parent or medical care giver of a diabetes patient) of impending hypoglycemic/ hyperglycemic events and thereby enable the patient to avoid extreme hypoglycemic/hyperglycemic excursions as well as minimize deviations outside the normal glucose range, thus preventing both life-threatening events and the debilitating complications associated with diabetes. It is anticipated that CGM devices will utilize constant feedback of analytical information from a glucose sensor to activate an insulin delivery pump, thereby ultimately realizing the concept of an artificial pancreas. Depending on whether the CGM device penetrates/breaks the skin and/or the sample is measured extracorporeally, these devices can be categorized as totally invasive, minimally invasive, and noninvasive. In addition, CGM devices are further classified according to the transduction mechanisms used for glucose sensing (i.e., electrochemical, optical, and piezoelectric). However, at present, most of these technologies are plagued by a variety of issues that affect their accuracy and long-term performance. This article presents a critical comparison of existing CGM technologies, highlighting critical issues of device accuracy, foreign body response, calibration, and miniaturization. An outlook on future developments with an emphasis on long-term reliability and performance is also presented. © Diabetes Technology Society.

References Powered by Scopus

STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

42255Citations
N/AReaders
Get full text

The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes Mellitus

0
23985Citations
N/AReaders
Get full text

Evaluating clinical accuracy of systems for self-monitoring of blood glucose

1241Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Electrochemical glucose sensors in diabetes management: An updated review (2010-2020)

640Citations
N/AReaders
Get full text

Wearables in Medicine

426Citations
N/AReaders
Get full text

Device integration of electrochemical biosensors

325Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010). Technologies for continuous glucose monitoring: Current problems and future promises. Journal of Diabetes Science and Technology, 4(6), 1540–1562. https://doi.org/10.1177/193229681000400632

Readers over time

‘10‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘25015304560

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 141

65%

Researcher 47

22%

Professor / Associate Prof. 22

10%

Lecturer / Post doc 7

3%

Readers' Discipline

Tooltip

Engineering 88

44%

Medicine and Dentistry 47

24%

Chemistry 33

17%

Agricultural and Biological Sciences 32

16%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 13

Save time finding and organizing research with Mendeley

Sign up for free
0