Abstract

A cone beam circular half-scan scheme is becoming an attractive imaging method in cone beam CT since it improves the temporal resolution. Traditionally, the redundant data in the circular half-scan range is weighted by a central scanning plane-dependent weighting function; FDK algorithm is then applied on the weighted projection data for reconstruction. However, this scheme still suffers the attenuation coefficient drop inherited with FDK when the cone angle becomes large. A new heuristic cone beam geometry-dependent weighting scheme is proposed based on the idea that there exists less redundancy for the projection data away from the central scanning plane. The performance of FDKHSCW scheme is evaluated by comparing it to the FDK full-scan (FDKFS) scheme and the traditional FDK half-scan scheme with Parker's fan beam weighting function (FDKHSFW). Computer simulation is employed and conducted on a 3D Shepp-Logan phantom. The result illustrates a correction of FDKHSCW to the attenuation coefficient drop in the off-scanning plane associated with FDKFS and FDKHSFW while maintaining the same spatial resolution. Copyright © 2006 D. Yang and R. Ning.

References Powered by Scopus

Practical cone-beam algorithm

5551Citations
N/AReaders
Get full text

Optimal short scan convolution reconstruction for fan beam CT

522Citations
N/AReaders
Get full text

3D cone-beam CT reconstruction for circular trajectories

196Citations
N/AReaders
Get full text

Cited by Powered by Scopus

X-Ray imaging: Fundamentals, industrial techniques and applications

85Citations
N/AReaders
Get full text

NPS characterization and evaluation of a cone beam CT breast imaging system

27Citations
N/AReaders
Get full text

Analytical reconstruction algorithm for multiple source-translation computed tomography (mSTCT)

14Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Yang, D., & Ning, R. (2006). FDK half-scan with a heuristic weighting scheme on a flat panel detector-based cone beam CT (FDKHSCW). International Journal of Biomedical Imaging, 2006. https://doi.org/10.1155/IJBI/2006/83983

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 14

58%

Researcher 9

38%

Lecturer / Post doc 1

4%

Readers' Discipline

Tooltip

Engineering 7

39%

Physics and Astronomy 4

22%

Medicine and Dentistry 4

22%

Computer Science 3

17%

Save time finding and organizing research with Mendeley

Sign up for free