Smartphone based bacterial detection using biofunctionalized fluorescent nanoparticles

95Citations
Citations of this article
106Readers
Mendeley users who have this article in their library.
Get full text

Abstract

We are describing immunochromatographic test strips with smart phone-based fluorescence readout. They are intended for use in the detection of the foodborne bacterial pathogens Salmonella spp. and Escherichia coli O157. Silica nanoparticles (SiNPs) were doped with FITC and Ru(bpy), conjugated to the respective antibodies, and then used in a conventional lateral flow immunoassay (LFIA). Fluorescence was recorded by inserting the nitrocellulose strip into a smart phone-based fluorimeter consisting of a light weight (40 g) optical module containing an LED light source, a fluorescence filter set and a lens attached to the integrated camera of the cell phone in order to acquire high-resolution fluorescence images. The images were analysed by exploiting the quick image processing application of the cell phone and enable the detection of pathogens within few minutes. This LFIA is capable of detecting pathogens in concentrations as low as 105 cfu mL−1 directly from test samples without pre-enrichment. The detection is one order of magnitude better compared to gold nanoparticle-based LFIAs under similar condition. The successful combination of fluorescent nanoparticle-based pathogen detection by LFIAs with a smart phone-based detection platform has resulted in a portable device with improved diagnosis features and having potential application in diagnostics and environmental monitoring. [Figure not available: see fulltext.].

References Powered by Scopus

This article is free to access.

Get full text

Cited by Powered by Scopus

430Citations
589Readers
Get full text
229Citations
260Readers
Get full text
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Rajendran, V. K., Bakthavathsalam, P., & Jaffar Ali, B. M. (2014). Smartphone based bacterial detection using biofunctionalized fluorescent nanoparticles. Microchimica Acta, 181(15–16), 1815–1821. https://doi.org/10.1007/s00604-014-1242-5

Readers over time

‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘2406121824

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 51

67%

Researcher 16

21%

Professor / Associate Prof. 5

7%

Lecturer / Post doc 4

5%

Readers' Discipline

Tooltip

Engineering 23

38%

Chemistry 21

34%

Agricultural and Biological Sciences 13

21%

Chemical Engineering 4

7%

Save time finding and organizing research with Mendeley

Sign up for free
0