In vitro stability and compatibility of tenecteplase in central venous access devices

3Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Central venous access devices (CVADs) aid in the delivery of nutritional support, infusion therapy, and hemodialysis. Maintaining continuous flow through these devices is challenging, because they are susceptible to complications such as thrombi occlusion. Therefore, CVADs may require treatment with anticoagulant or thrombolytic agents. Using these agents as locking solutions has been widely investigated; however, few publications have described the compatibility of the therapeutic with the CVAD itself. The objective of this investigation was to evaluate the in vitro stability and compatibility of a thrombolytic biologic agent, tenecteplase, with various CVAD materials. Tenecteplase was reconstituted to 1mg/mL with either sterile water for injection or bacteriostatic water for injection (0.9% benzyl alcohol) then incubated in glass vials, polysulfone/silicone vascular access ports, and polyurethane or silicone catheters for up to 96 hours. Biochemical assays including protein monomer, protein one-chain, and in vitro bioactivity were used to assess tenecteplase's compatibility with the investigated diluents and materials every 24 hours. Antimicrobial testing was also performed for up to 28 days on bacteriostatic water for injection-reconstituted samples only. Our results showed tenecteplase to be compatible with both types of diluents (in glass vials) and catheters for up to 72 hours. Furthermore, tenecteplase was compatible with the polysulfone/silicone vascular access ports for up to 24 hours. Finally, bacteriostatic water for injection-reconstituted tenecteplase effectively met USP criteria for the inhibition of growth of micro-organisms. This study serves as an example of a best practice to evaluate the in vitro stability and compatibility of a biologic agent with CVAD materials. © 2011 The Authors. Hemodialysis International © 2011 International Society for Hemodialysis.

References Powered by Scopus

Preventing complications of central venous catheterization

1808Citations
N/AReaders
Get full text

A faster-acting and more potent form of tissue plasminogen activator

339Citations
N/AReaders
Get full text

Silastic cuffed catheters for hemodialysis vascular access: Thrombolytic and mechanical correction of malfunction

173Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Tenecteplase in Acute Stroke: What About the Children?

6Citations
N/AReaders
Get full text

The Effect of High Storage Temperature on the Stability and Efficacy of Lyophilized Tenecteplase

2Citations
N/AReaders
Get full text

Incompatibility of esmolol hydrochloride and furosemide in a central venous access port

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lentz, Y. K., Joyce, M., & Lam, X. (2011). In vitro stability and compatibility of tenecteplase in central venous access devices. Hemodialysis International, 15(2), 264–272. https://doi.org/10.1111/j.1542-4758.2011.00541.x

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

63%

Researcher 2

25%

Professor / Associate Prof. 1

13%

Readers' Discipline

Tooltip

Medicine and Dentistry 4

50%

Nursing and Health Professions 2

25%

Design 1

13%

Materials Science 1

13%

Save time finding and organizing research with Mendeley

Sign up for free