Evaluating the effects of variation in CT scanning parameters on the image quality and Hounsfield units for optimization of dose in radiotherapy treatment planning: A semi-anthropomorphic thorax phantom study

5Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Aim: The diagnosis accuracy of computed tomography (CT) systems and the reliability of calculated Hounsfield Units (HUs) are critical in tumor detection and cancer patients' treatment planning. This study evaluated the effects of scan parameters (Kilovoltage peak or kVp, milli-Ampere-second or mAS reconstruction kernels and algorithms, reconstruction field of view, and slice thickness) on image quality, HUs, and the calculated dose in the treatment planning system (TPS). Materials and Methods: A quality dose verification phantom was scanned several times by a 16-slice Siemens CT scanner. The DOSIsoft ISO gray TPS was applied for dose calculations. The SPSS.24 software was used to analyze the results and the P-value <0.05 was considered significant. Results: Reconstruction kernels and algorithms significantly affected noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The noise increased and CNR decreased by raising the sharpness of reconstruction kernels. SNR and CNR had considerable increments at iterative reconstruction compared with the filtered back-projection algorithm. The noise decreased by raising mAS in soft tissues. Also, KVp had a significant effect on HUs. TPS - calculated dose variations were less than 2% for mediastinum and backbone and less than 8% for rib. Conclusions: Although HU variation depends on image acquisition parameters across a clinically feasible range, its dosimetric impact on the calculated dose in TPS can be neglected. Hence, it can be concluded that the optimized values of scan parameters can be applied to obtain the maximum diagnostic accuracy and calculate HUs more precisely without affecting the calculated dose in the treatment planning of cancer patients.

References Powered by Scopus

State of the Art: Iterative CT reconstruction techniques<sup>1</sup>

579Citations
N/AReaders
Get full text

Principles of CT: Radiation dose and image quality

316Citations
N/AReaders
Get full text

Multi-detector row CT attenuation measurements: Assessment of intra- and interscanner variability with an anthropomorphic body CT phantom

228Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Assessment of CBCT gray value in different regions-of-interest and fields-of-view compared to Hounsfield unit

7Citations
N/AReaders
Get full text

Advances and Applications of Three-Dimensional-Printed Patient-Specific Chest Phantoms in Radiology: A Systematic Review

1Citations
N/AReaders
Get full text

Sparse‑view cone‑beam computed tomography iterative reconstruction based on new multi‑gradient direction total variation

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Sorooshfard, E., Tahmasbi, M., Chegeni, N., & Birgani, M. J. T. (2023). Evaluating the effects of variation in CT scanning parameters on the image quality and Hounsfield units for optimization of dose in radiotherapy treatment planning: A semi-anthropomorphic thorax phantom study. Journal of Cancer Research and Therapeutics, 19(2), 426–434. https://doi.org/10.4103/jcrt.jcrt_260_21

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

100%

Readers' Discipline

Tooltip

Engineering 1

33%

Agricultural and Biological Sciences 1

33%

Nursing and Health Professions 1

33%

Save time finding and organizing research with Mendeley