Effect of acetic NaF solution on the corrosion behavior of stainless steel orthodontic brackets

9Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

Abstract

This study assessed the effect of acetic NaF solutions on stainless steel orthodontic brackets. Acetic acid was added to a 0.1% NaF solution to make two solutions, one with pH 3.5 and the other with pH 6. For the two different stainless steel brackets (Tomy, Dentaurum) used in this study, they had a similar elemental composition -except with Mo (molybdenum) in the Tomy bracket. The brackets were then immersed in the prepared test solutions for three days and their responses evaluated. In terms of hydrofluoric acid (HF) concentration, the 0.1%/pH 3.5 solution showed a high HF concentration at 227 ppm, while that of 0.1%/pH 6 solution was very low at 7 ppm. In terms of color change and element release, only the Dentaurum brackets in 0.1%/pH 3.5 solution showed an appreciable color change (Δ E* = 4.0) and released a great amount of elements (Fe, Cr, Ni, Mn) after three days. Otherwise, regardless of pH value and product, only minor color change (Δ E* < 1.0) and negligible element release occurred. In terms of surface modification, no visible changes in surface morphology were observed in any product after immersion in test solutions.

References Powered by Scopus

Role of Streptococcus mutans in human dental decay

2585Citations
N/AReaders
Get full text

Manganese

220Citations
N/AReaders
Get full text

Nickel allergy in adolescents in relation to orthodontic treatment and piercing of ears.

198Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Release of metal ions from orthodontic appliances by in vitro studies: A systematic literature review

72Citations
N/AReaders
Get full text

Corrosion mechanism of Ti-Cr alloys in solution containing fluoride

31Citations
N/AReaders
Get full text

Corrosion and biocompatibility behaviour of zirconia coating by EBPVD for biomedical applications

28Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Jang, H. S., Son, W. S., Park, S. B., Kim, H. I., & Kwon, Y. H. (2006). Effect of acetic NaF solution on the corrosion behavior of stainless steel orthodontic brackets. Dental Materials Journal, 25(2), 339–344. https://doi.org/10.4012/dmj.25.339

Readers over time

‘11‘12‘13‘14‘15‘18‘19‘20‘21‘22‘2302468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 9

69%

Professor / Associate Prof. 3

23%

Researcher 1

8%

Readers' Discipline

Tooltip

Medicine and Dentistry 10

63%

Agricultural and Biological Sciences 3

19%

Chemistry 2

13%

Engineering 1

6%

Save time finding and organizing research with Mendeley

Sign up for free
0