Impact of bridge heterology on functional parameters of ELISA for 17α-methyltestosterone

0Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.
Get full text

Abstract

In this study, we have developed bridge heterologous ELISA for the detection of 17α- Methyltestosterone by incorporating aromatic spacers between 17α-Methyltestosterone-3-Carboxymethyloxime and Horseradish peroxidase label through N-hydroxysuccinimide mediated carbodiimide reaction method. The immunogen 17α-Methyltestosterone-3-Carboxymethyloxime-Bovine serum albumin used to generate the antibody was also prepared by the N-hydroxysuccinimide mediated carbodiimide reaction without using any spacer. We have studied the impact of bridge/aromatic spacers on functional parameters i.e. sensitivity, affinity and ED50 of the bridge heterologous assay and compared it with homologous assay. The five combinations of bridge heterologous assay using 17α-Methyl testosterone-3-CMO-BSA antiserum and 17α-MT-3-CMO-4,4’-Diaminodiphenyl sulphide-HRP, 17α MT-3-CMO-4,4’-Oxydianiline-HRP, 17α-MT-3-CMO-Benzidine-HRP, 17α- MT-3-CMO-p-Phenylenediamine-HRP and 17α-MT-3-CMO-Dapson-HRP enzyme conjugates were evaluated. Out of these five combinations, the combination 17α-MT-3-CMO-BSA with 17α-MT-3-CMO-Benzidine-HRP showed the best results. Sensitivity, affinity and ED50 were improved and found to be 0.02 ng/mL, 0.086 × 10−8 L/mol and 2.95 ng/mL than homologous assay where Sensitivity, affinity and ED50 were 0.11 ng/mL, 0.02 × 10−8 L/mol and 5.78 ng/mL respectively. The cross-reactivity for this bridge heterologous assay combination was seen with only 4 steroids (6-hydrotestosterone- 6%, Testosterone-5.14%, Danazol-0.9% and Nandrolone-0.85%) instead of eight steroids (6-hydrotestosterone-43.75%, Testosterone-38.3%, Danazol-25.14%, Androstenediol-19.16%, Nandrolone-19%, Metandienone-5%, Androstenedione-3.52%, and 17α dimethyltestosterone-2%) as in homologous assay out of 59 structurally related steroids. Thus, the results of this study conclude that the incorporation of aromatic spacer (bridge) in enzyme conjugate has a crucial role in improving sensitivity, specificity, ED50 and affinity of the developed assay. The assay was then studied for parameters such as recovery (97.4%–108.6%), precision (Inter and Intra-assay coefficient of variation <10%), correlation coefficient (R2 = 0.96) by comparing with the commercial kit and validated by measuring levels of 17α- methyltestosterone in rat serum after administering them.

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Verma, D., Shrivastav, T. G., & Thakur, S. C. (2023). Impact of bridge heterology on functional parameters of ELISA for 17α-methyltestosterone. Journal of Immunological Methods, 522. https://doi.org/10.1016/j.jim.2023.113572

Save time finding and organizing research with Mendeley

Sign up for free