Abstract

Purpose: To increase the efficiency of retinal image grading, algorithms for automated grading have been developed, such as the IDx-DR 2.0 device. We aimed to determine the ability of this device, incorporated in clinical work flow, to detect retinopathy in persons with type 2 diabetes. Methods: Retinal images of persons treated by the Hoorn Diabetes Care System (DCS) were graded by the IDx-DR device and independently by three retinal specialists using the International Clinical Diabetic Retinopathy severity scale (ICDR) and EURODIAB criteria. Agreement between specialists was calculated. Results of the IDx-DR device and experts were compared using sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), distinguishing between referable diabetic retinopathy (RDR) and vision-threatening retinopathy (VTDR). Area under the receiver operating characteristic curve (AUC) was calculated. Results: Of the included 1415 persons, 898 (63.5%) had images of sufficient quality according to the experts and the IDx-DR device. Referable diabetic retinopathy (RDR) was diagnosed in 22 persons (2.4%) using EURODIAB and 73 persons (8.1%) using ICDR classification. Specific intergrader agreement ranged from 40% to 61%. Sensitivity, specificity, PPV and NPV of IDx-DR to detect RDR were 91% (95% CI: 0.69–0.98), 84% (95% CI: 0.81–0.86), 12% (95% CI: 0.08–0.18) and 100% (95% CI: 0.99–1.00; EURODIAB) and 68% (95% CI: 0.56–0.79), 86% (95% CI: 0.84–0.88), 30% (95% CI: 0.24–0.38) and 97% (95% CI: 0.95–0.98; ICDR). The AUC was 0.94 (95% CI: 0.88–1.00; EURODIAB) and 0.87 (95% CI: 0.83–0.92; ICDR). For detection of VTDR, sensitivity was lower and specificity was higher compared to RDR. AUC's were comparable. Conclusion: Automated grading using the IDx-DR device for RDR detection is a valid method and can be used in primary care, decreasing the demand on ophthalmologists.

References Powered by Scopus

Global prevalence and major risk factors of diabetic retinopathy

3649Citations
N/AReaders
Get full text

Global estimates of diabetes prevalence for 2013 and projections for 2035

3604Citations
N/AReaders
Get full text

Proposed international clinical diabetic retinopathy and diabetic macular edema disease severity scales

3024Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The state of artificial intelligence-based FDA-approved medical devices and algorithms: an online database

666Citations
N/AReaders
Get full text

Screening for diabetic retinopathy: new perspectives and challenges

423Citations
N/AReaders
Get full text

A deep learning system for detecting diabetic retinopathy across the disease spectrum

389Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

van der Heijden, A. A., Abramoff, M. D., Verbraak, F., van Hecke, M. V., Liem, A., & Nijpels, G. (2018). Validation of automated screening for referable diabetic retinopathy with the IDx-DR device in the Hoorn Diabetes Care System. Acta Ophthalmologica, 96(1), 63–68. https://doi.org/10.1111/aos.13613

Readers over time

‘18‘19‘20‘21‘22‘23‘24‘25015304560

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 69

66%

Researcher 27

26%

Professor / Associate Prof. 6

6%

Lecturer / Post doc 3

3%

Readers' Discipline

Tooltip

Medicine and Dentistry 71

68%

Computer Science 17

16%

Engineering 10

10%

Nursing and Health Professions 6

6%

Article Metrics

Tooltip
Mentions
News Mentions: 2
Social Media
Shares, Likes & Comments: 33

Save time finding and organizing research with Mendeley

Sign up for free
0