Measurement of gastric emptying in infants with pyloric stenosis using applied potential tomography

14Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

Gastric emptying in a group of 49 vomiting infants with infantile hypertrophic pyloric stenosis (IHPS) was investigated using applied potential tomography. Fourteen asymptomatic infants were also studied as a control group. A Dioralyte test feed (25 ml/kg/feed) was used for all the studies. The infants with IHPS were investigated before and at two, four, and seven days after an operation; the other infants were investigated once. The results show that the infants with IHPS have no or little gastric emptying before the operation and gradually return to normal emptying by the seventh day after the operation. A significant difference in gastric emptying was noted between the control infants and the infants with IHPS before and at two and four days after the operation. The applied potential tomography method is suitable for studying gastric emptying in infants, with no morbidity nor complications. It also allows multiple studies to be performed without upset or discomfort.

References Powered by Scopus

Applied potential tomography: Possible clinical applications

242Citations
N/AReaders
Get full text

Applied Potential Tomography: A New Noninvasive Technique for Measuring Gastric Emptying

93Citations
N/AReaders
Get full text

GASTRIC EMPTYING IN NEWBORNS AND YOUNG INFANTS: Measurement of the Rate of Emptying Using Indium‐113m‐Microcolloid

77Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Effect of fortifying breast milk on gastric emptying

60Citations
N/AReaders
Get full text

Review of paediatric gastrointestinal physiology relevant to the absorption of orally administered medicines

39Citations
N/AReaders
Get full text

Gastric emptying in patients with type I diabetes mellitus

35Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Nour, S., Mangnall, Y., Dickson, J. A. S., Pearse, R., & Johnson, A. G. (1993). Measurement of gastric emptying in infants with pyloric stenosis using applied potential tomography. Archives of Disease in Childhood, 68(4), 484–486. https://doi.org/10.1136/adc.68.4.484

Readers' Seniority

Tooltip

Professor / Associate Prof. 3

43%

PhD / Post grad / Masters / Doc 3

43%

Lecturer / Post doc 1

14%

Readers' Discipline

Tooltip

Medicine and Dentistry 3

50%

Social Sciences 1

17%

Physics and Astronomy 1

17%

Engineering 1

17%

Save time finding and organizing research with Mendeley

Sign up for free