Does an increase in the sensitivity of serum thyrotropin assays reduce diagnostic costs for thyroid disease in the community?

6Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

Many authorities now advocate that the first-line assessment of thyroid function should be measurement of thyrotropin (TSH). The latest serum TSH assays (third generation) are more sensitive than the second generation but the reagents are more costly. We have examined whether overall assay reagent costs would be higher or lower with a third-generation assay, in a laboratory that serves a population of almost 500 000. In a prospective study over six weeks, 505 samples with a second-generation serum TSH less than 0.5 mU/L (303 for screening and 202 for monitoring thyroxine therapy) had an additional third-generation TSH analysis. With a second-generation assay for screening, 11% more free thyroxine (FT4) measurements were required to exclude thyrotoxicosis but there was a 42% saving on the reagent budget compared with a third-generation assay. In patients taking thyroxine, 33% more FT4 measurements were required to exclude over-replacement but the calculated saving in reagent costs was 53%. The costs of all other aspects of the two methods were similar. In this community-based sample, the improvement in sensitivity yielded by the third-generation assay at the lower end of the normal range reduced the number of confirmatory FT4 levels required to exclude thyrotoxicosis or over-replacement with thyroxine, but reagent costs were nevertheless higher than for second-generation assays. In financial terms, there is little justification for use of assays with sensitivity greater than the second generation (0.1 mU/L).

References Powered by Scopus

The incidence of thyroid disorders in the community: A twenty-year follow-up of the Whickham Survey

2023Citations
N/AReaders
Get full text

Prevalence and follow‐up of abnormal thyrotrophin (TSH) concentrations in the elderly in the United Kingdom

516Citations
N/AReaders
Get full text

A NEW STRATEGY FOR THYROID FUNCTION TESTING

122Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Use of high-capacity surface with oriented recombinant antibody fragments in a 5-min immunoassay for thyroid-stimulating hormone

19Citations
N/AReaders
Get full text

Utility of third generation thyrotropin assays in thyroid function testing

18Citations
N/AReaders
Get full text

Thyroid physiology and thyroid function testing

13Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Vanderpump, M. P. J., Neary, R. H., Manning, K., & Clayton, R. N. (1997). Does an increase in the sensitivity of serum thyrotropin assays reduce diagnostic costs for thyroid disease in the community? Journal of the Royal Society of Medicine, 90(10), 547–550. https://doi.org/10.1177/014107689709001006

Readers over time

‘10‘12‘13‘14‘15‘20‘22‘23‘2500.511.52

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

50%

Professor / Associate Prof. 2

33%

Researcher 1

17%

Readers' Discipline

Tooltip

Neuroscience 1

25%

Social Sciences 1

25%

Agricultural and Biological Sciences 1

25%

Medicine and Dentistry 1

25%

Save time finding and organizing research with Mendeley

Sign up for free
0