Performance of bioelectrical impedance analysis compared to dual X-ray absorptiometry (DXA) in Veterans with COPD

16Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

We examined the performance of a commercially-available handheld bioimpedance (BIA) device relative to dual X-ray absorptiometry (DXA) to assess body composition differences among Veterans with chronic obstructive pulmonary disease (COPD). Body composition was measured using DXA and BIA (Omron HBF-306C) at a single time point. Correlations between BIA- and DXA-assessed percent fat, fat mass, and fat-free mass were analyzed using Spearman (ρ) and Lin Concordance Correlation Coefficients (ρc). Mean differences in fat mass were visualized using Bland–Altman plots. Subgroup analyses by obesity status (BMI < 30 versus ≥ 30) were performed. Among 50 participants (96% male; mean age: 69.5 ± 6.0 years), BIA-assessed fat mass was strongly correlated (ρ = 0.94) and demonstrate excellent concordance (ρc = 0.95, [95%CI: 0.93–0.98]) with DXA, with a mean difference of 2.7 ± 3.2 kg between BIA and DXA. Although Spearman correlations between BIA- and DXA-assessed percent fat and fat-free mass were strong (ρ = 0.8 and 0.91, respectively), concordance values were only moderate (ρc = 0.67 and 0.74, respectively). Significantly stronger correlations were observed for obese relative to non-obese subjects for total percent fat (ρobese = 0.85 versus ρnon-obese = 0.5) and fat mass (ρobese = 0.96 versus ρnon-obese = 0.84). A handheld BIA device demonstrated high concordance with DXA for fat mass and moderate concordance for total percent fat and fat-free mass. ClinicalTrials.gov: NCT02099799.

References Powered by Scopus

STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

42255Citations
N/AReaders
Get full text

A concordance correlation coefficient to evaluate reproducibility

6911Citations
N/AReaders
Get full text

Total body water volumes for adult males and females estimated from simple anthropometric measurements

1296Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Update on the Etiology, Assessment, and Management of COPD Cachexia: Considerations for the Clinician

12Citations
N/AReaders
Get full text

Telomere Length and Risk of Incident Fracture and Arthroplasty: Findings From UK Biobank

5Citations
N/AReaders
Get full text

Accuracy of bioimpedance equations for measuring body composition in a cohort of 2134 patients with obesity

5Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Cruz Rivera, P. N., Goldstein, R. L., Polak, M., Lazzari, A. A., Moy, M. L., & Wan, E. S. (2022). Performance of bioelectrical impedance analysis compared to dual X-ray absorptiometry (DXA) in Veterans with COPD. Scientific Reports, 12(1). https://doi.org/10.1038/s41598-022-05887-4

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

60%

Professor / Associate Prof. 3

30%

Lecturer / Post doc 1

10%

Readers' Discipline

Tooltip

Sports and Recreations 3

38%

Nursing and Health Professions 2

25%

Medicine and Dentistry 2

25%

Agricultural and Biological Sciences 1

13%

Save time finding and organizing research with Mendeley

Sign up for free