The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics

15Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

Abstract

Surfactant liquid-membrane type sensors are usually made of a PVC, ionophore and a plasticizer. Plasticizers soften the PVC. Due to their lipophilicity, they influence the ion exchange across the membrane, ionophore solubility, membrane resistance and, consequently, the analytical signal. We used the DMI-TPB as an ionophore, six different plasticizers [2-nitrophenyl-octyl-ether (P1), bis(2-ethylhexyl) phthalate (P2), bis(2-ethylhexyl) sebacate (P3), 2-nitrophenyl phenyl ether (P4), dibutyl phthalate (P5) and dibutyl sebacate (P6)] and a PVC to produce ionic surfactant sensors. Sensor formulation with P1 showed the best potentiometric response to four usually used cationic surfactant, with the lowest LOD, 7 × 10−7 M; and potentiometric titration curves with well-defined and sharp inflexion points. The sensor with P6 showed the lowest analytical performances. Surfactant sensor with P1 was selected for quantification of cationic surfactant in model solutions and commercial samples of disinfectants and antiseptics. It showed high accuracy and precision in all determinations, with recovery from 98.2 to 99.6, and good agreement with the results obtained with surfactant sensor used as a referent one, and a standard two-phase titration method. RDS values were lower than 0.5% for all determinations.

References Powered by Scopus

Recommendations for nomenclature of ion-selective electrodes (recommendations 1975)

870Citations
N/AReaders
Get full text

Lifetime of Neutral-Carrier-Based Liquid Membranes in Aqueous Samples and Blood and the Lipophilicity of Membrane Components

240Citations
N/AReaders
Get full text

Plasticizers for liquid polymeric membranes of ion-selective chemical sensors

187Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Preparation of new polymeric phases for thin-film liquid phase microextraction (TF-LPME) of selected organic pollutants

17Citations
N/AReaders
Get full text

A new sensor for direct potentiometric determination of thiabendazole in fruit peels using the Gran method

10Citations
N/AReaders
Get full text

Dibenzo-18-crown-6-based carbon paste sensors for the nanomolar potentiometric determination of daclatasvir dihydrochloride: An anti-HCV drug and a potential candidate for treatment of SARS-CoV-2

10Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Sakač, N., Madunić-čačić, D., Karnaš, M., Ðurin, B., Kovač, I., & Jozanović, M. (2021). The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics. Sensors, 21(10). https://doi.org/10.3390/s21103535

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

36%

Professor / Associate Prof. 3

21%

Lecturer / Post doc 3

21%

Researcher 3

21%

Readers' Discipline

Tooltip

Chemistry 9

69%

Chemical Engineering 2

15%

Nursing and Health Professions 1

8%

Pharmacology, Toxicology and Pharmaceut... 1

8%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 24

Save time finding and organizing research with Mendeley

Sign up for free