Effect of femoral stem surface coating on clinical and radiographic outcomes of cementless primary total hip arthroplasty: a patient-matched retrospective study

11Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: This study aims to determine whether changing the stem coating grants superior outcomes at a minimum follow-up of five years. Methods: Retrospective review of a consecutive series of primary total hip arthroplasties (THAs) operated by direct anterior approach between 01/01/2013 and 31/12/2014. Two stems were compared, which were identical except for their surface coating; “the Original stem” was fully coated with hydroxyapatite (HA), while “the ProxCoat stem” was proximally coated with plasma-sprayed titanium and HA. Matching was performed. Clinical assessment included modified Harris hip score (mHHS), Oxford hip score (OHS), and forgotten joint score (FJS). Radiographic assessment evaluated alignment, subsidence, pedestal formation, heterotopic ossification, radiolucent lines ≥ 2 mm, spot welds, cortical hypertrophy, and osteolysis. Results: 232 hips received the Original stem and 167 the ProxCoat stem, from which respectively five hips (2.2%) and no hips (0%) underwent revision. Matching identified two groups of 91 patients, with comparable patient demographics. At > five years follow-up, there were no differences in OHS (16 ± 6 vs 15 ± 5; p = 0.075) nor FJS (81 ± 26 vs 84 ± 22; p = 0.521), but there were differences in mHHS (89 ± 15 vs 92 ± 12; p = 0.042). There were no differences in alignment, subsidence, pedestal formation, heterotopic ossification, cortical hypertrophy, and osteolysis. There were differences in prevalence of proximal radiolucent lines (12% vs 0%; p < 0.001) and distal spot welds (24% vs 54%; p < 0.001). Conclusion: At a minimum follow-up of five years, this study on matched patients undergoing primary THA found that ProxCoat stems results in significantly fewer radiolucent lines, more spot welds, and less revisions than Original stems, thus suggesting better bone ingrowth.

References Powered by Scopus

Ectopic ossification following total hip replacement. Incidence and a method of classification

2821Citations
N/AReaders
Get full text

Structural and cellular assessment of bone quality of proximal femur

701Citations
N/AReaders
Get full text

The anatomic basis of femoral component design

664Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Updates on Biomaterials Used in Total Hip Arthroplasty (THA)

9Citations
N/AReaders
Get full text

The influence of prosthetic positioning and proximal femoral morphology on leg length discrepancy and early clinical outcomes of cementless total hip arthroplasty

3Citations
N/AReaders
Get full text

Improved radiographic outcomes and decreased complications rate on the femoral side can be achieved by a novel designed whole-process robotic assisted hip system for total hip arthroplasty: a prospective randomized controlled trial

2Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Viamont-Guerra, M. R., Ramos-Pascual, S., Saffarini, M., Sales, J., & Laude, F. (2023). Effect of femoral stem surface coating on clinical and radiographic outcomes of cementless primary total hip arthroplasty: a patient-matched retrospective study. International Orthopaedics, 47(1), 165–174. https://doi.org/10.1007/s00264-022-05629-1

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

57%

Lecturer / Post doc 2

29%

Researcher 1

14%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

60%

Engineering 3

30%

Arts and Humanities 1

10%

Article Metrics

Tooltip
Mentions
News Mentions: 10

Save time finding and organizing research with Mendeley

Sign up for free