A frame orientation optimisation method for consistent interpretation of kinematic signals

5Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In clinical movement biomechanics, kinematic data are often depicted as waveforms (i.e. signals), characterising the motion of articulating joints. Clinically meaningful interpretations of the underlying joint kinematics, however, require an objective understanding of whether two different kinematic signals actually represent two different underlying physical movement patterns of the joint or not. Previously, the accuracy of IMU-based knee joint angles was assessed using a six-degrees-of-freedom joint simulator guided by fluoroscopy-based signals. Despite implementation of sensor-to-segment corrections, observed errors were clearly indicative of cross-talk, and thus inconsistent reference frame orientations. Here, we address these limitations by exploring how minimisation of dedicated cost functions can harmonise differences in frame orientations, ultimately facilitating consistent interpretation of articulating joint kinematic signals. In this study, we present and investigate a frame orientation optimisation method (FOOM) that aligns reference frames and corrects for cross-talk errors, hence yielding a consistent interpretation of the underlying movement patterns. By executing optimised rotational sequences, thus producing angular corrections around each axis, we enable a reproducible frame definition and hence an approach for reliable comparison of kinematic data. Using this approach, root-mean-square errors between the previously collected (1) IMU-based data using functional joint axes, and (2) simulated fluoroscopy-based data relying on geometrical axes were almost entirely eliminated from an initial range of 0.7°–5.1° to a mere 0.1°–0.8°. Our results confirm that different local segment frames can yield different kinematic patterns, despite following the same rotation convention, and that appropriate alignment of reference frame orientation can successfully enable consistent kinematic interpretation.

References Powered by Scopus

A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee

3170Citations
N/AReaders
Get full text

A gait analysis data collection and reduction technique

2447Citations
N/AReaders
Get full text

Measurement of lower extremity kinematics during level walking

2302Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Validation of Inertial-Measurement-Unit-Based Ex Vivo Knee Kinematics during a Loaded Squat before and after Reference-Frame-Orientation Optimisation

1Citations
N/AReaders
Get full text

A reproducible representation of healthy tibiofemoral kinematics during stair descent using REFRAME – part I: REFRAME foundations and validation

0Citations
N/AReaders
Get full text

Conceptual foundations of a REFRAME-based approach to discriminate across total knee implant designs based on the positions of functional centres of rotation

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ortigas Vásquez, A., Taylor, W. R., Maas, A., Woiczinski, M., Grupp, T. M., & Sauer, A. (2023). A frame orientation optimisation method for consistent interpretation of kinematic signals. Scientific Reports, 13(1). https://doi.org/10.1038/s41598-023-36625-z

Readers over time

‘23‘24‘2502468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

63%

Researcher 3

38%

Readers' Discipline

Tooltip

Engineering 4

57%

Medicine and Dentistry 2

29%

Sports and Recreations 1

14%

Save time finding and organizing research with Mendeley

Sign up for free
0