Determination of total polyphenols content in green tea using FT-NIR spectroscopy and different PLS algorithms

271Citations
Citations of this article
118Readers
Mendeley users who have this article in their library.
Get full text

Abstract

This paper attempted the feasibility to determine content total polyphenols content in green tea with near infrared (NIR) spectroscopy coupled with an appropriate multivariate calibration method. Partial least squares (PLS), interval PLS (iPLS) and synergy interval PLS (siPLS) algorithms were performed comparatively to calibrate regression model. The number of PLS components and the number of intervals were optimized according to root mean square error of cross-validation (RMSECV) in calibration set. The performance of the final model was evaluated according to root mean square error of prediction (RMSEP) and correlation coefficient (R) in prediction set. Experimental results showed that the performance of siPLS model is the best in contrast to PLS and iPLS. The optimal model was achieved with R = 0.9583 and RMSEP = 0.7327 in prediction set. This study demonstrated that NIR spectroscopy with siPLS algorithm could be used successfully to analysis of total polyphenols content in green tea, and revealed superiority of siPLS algorithm in contrast with other multivariate calibration methods. © 2007 Elsevier B.V. All rights reserved.

Figures

References Powered by Scopus

Interval partial least-squares regression (iPLS): A comparative chemometric study with an example from near-infrared spectroscopy

1299Citations
N/AReaders
Get full text

Inhibition of carcinogenesis by tea

864Citations
N/AReaders
Get full text

Sequential application of backward interval partial least squares and genetic algorithms for the selection of relevant spectral regions

394Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Extraction and Analysis of Polyphenols: Recent trends

269Citations
N/AReaders
Get full text

Determination of total volatile basic nitrogen (TVB-N) content and Warner-Bratzler shear force (WBSF) in pork using Fourier transform near infrared (FT-NIR) spectroscopy

253Citations
N/AReaders
Get full text

Gallic Acid: Review of the Methods of Determination and Quantification

228Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Chen, Q., Zhao, J., Liu, M., Cai, J., & Liu, J. (2008). Determination of total polyphenols content in green tea using FT-NIR spectroscopy and different PLS algorithms. Journal of Pharmaceutical and Biomedical Analysis, 46(3), 568–573. https://doi.org/10.1016/j.jpba.2007.10.031

Readers over time

‘09‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘250481216

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 50

60%

Researcher 18

21%

Professor / Associate Prof. 12

14%

Lecturer / Post doc 4

5%

Readers' Discipline

Tooltip

Agricultural and Biological Sciences 27

39%

Chemistry 24

35%

Engineering 12

17%

Biochemistry, Genetics and Molecular Bi... 6

9%

Save time finding and organizing research with Mendeley

Sign up for free
0