The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT

92Citations
Citations of this article
90Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: To investigate the sensitivity of various gamma criteria used in the gamma-index method for patient-specific volumetric modulated arc therapy (VMAT) quality assurance (QA) for stereotactic body radiation therapy (SBRT) using a flattening filter free (FFF) photon beam.Methods: Three types of intentional misalignments were introduced to original high-definition multi-leaf collimator (HD-MLC) plans. The first type, referred to Class Out, involved the opening of each bank of leaves. The second type, Class In, involved the closing of each bank of leaves. The third type, Class Shift, involved the shifting of each bank of leaves towards the ground. Patient-specific QAs for the original and the modified plans were performed with MapCHECK2 and EBT2 films. The sensitivity of the gamma-index method using criteria of 1%/1 mm, 1.5%/1.5 mm, 1%/2 mm, 2%/1 mm and 2%/2 mm was investigated with absolute passing rates according to the magnitudes of MLCs misalignments. In addition, the changes in dose-volumetric indicators due to the magnitudes of MLC misalignments were investigated. The correlations between passing rates and the changes in dose-volumetric indicators were also investigated using Spearman's rank correlation coefficient (γ).Results: The criterion of 2%/1 mm was able to detect Class Out and Class In MLC misalignments of 0.5 mm and Class Shift misalignments of 1 mm. The widely adopted clinical criterion of 2%/2 mm was not able to detect 0.5 mm MLC errors of the Class Out or Class In types, and also unable to detect 3 mm Class Shift errors. No correlations were observed between dose-volumetric changes and gamma passing rates (γ < 0.8).Conclusions: Gamma criterion of 2%/1 mm was found to be suitable as a tolerance level with passing rates of 90% and 80% for patient-specific VMAT QA for SBRT when using MapCHECK2 and EBT2 film, respectively. © 2014 Kim et al.

References Powered by Scopus

A technique for the quantitative evaluation of dose distributions

2393Citations
N/AReaders
Get full text

Stereotactic body radiation therapy: The report of AAPM Task Group 101

1708Citations
N/AReaders
Get full text

AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams

1355Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG-55

199Citations
N/AReaders
Get full text

IMRT QA: Selecting gamma criteria based on error detection sensitivity

52Citations
N/AReaders
Get full text

The effect of MLC speed and acceleration on the plan delivery accuracy of VMAT

48Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kim, J. in, Park, S. Y., Kim, H. J., Kim, J. H., Ye, S. J., & Park, J. M. (2014). The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT. Radiation Oncology, 9(1). https://doi.org/10.1186/1748-717X-9-167

Readers over time

‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘250481216

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 41

64%

Researcher 14

22%

Professor / Associate Prof. 6

9%

Lecturer / Post doc 3

5%

Readers' Discipline

Tooltip

Physics and Astronomy 40

62%

Medicine and Dentistry 17

26%

Nursing and Health Professions 5

8%

Engineering 3

5%

Save time finding and organizing research with Mendeley

Sign up for free
0