This study evaluated a method for prostate intensity-modulated radiation therapy (IMRT) based on edge-enhanced (EE) intensity in the presence of intrafraction organ deformation using the data of 37 patients treated with step-and-shoot IMRT. On the assumption that the patient setup error was already accounted for by image guidance, only organ deformation over the treatment course was considered. Once the clinical target volume (CTV), rectum, and bladder were delineated and assigned dose constraints for dose optimization, each voxel in the CTV derived from the DICOM RT-dose grid could have a stochastic dose from the different voxel location according to the probability density function as an organ deformation. The stochastic dose for the CTV was calculated as the mean dose at the location through changing the voxel location randomly 1000 times. In the EE approach, the underdose region in the CTV was delineated and optimized with higher dose constraints that resulted in an edge-enhanced intensity beam to the CTV. This was compared to a planning target volume (PTV) margin (PM) approach in which a CTV to PTV margin equivalent to the magnitude of organ deformation was added to obtain an optimized dose distribution. The total monitor units, number of segments, and conformity index were compared between the two approaches, and the dose based on the organ deformation of the CTV, rectum, and bladder was evaluated. The total monitor units, number of segments, and conformity index were significantly lower with the EE approach than with the PM approach, while maintaining the dose coverage to the CTV with organ deformation. The dose to the rectum and bladder were significantly reduced in the EE approach compared with the PM approach. We conclude that the EE approach is superior to the PM with regard to intrafraction organ deformation.

References Powered by Scopus

Tumour and normal tissue responses to fractionated non-uniform dose delivery

494Citations
N/AReaders
Get full text

Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation

451Citations
N/AReaders
Get full text

Optimization of intensity-modulated radiotherapy plans based on the equivalent uniform dose

341Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The accuracy and precision of Kilovoltage Intrafraction Monitoring (KIM) six degree-of-freedom prostate motion measurements during patient treatments

17Citations
N/AReaders
Get full text

Minimum non-isotropic and asymmetric margins for taking into account intrafraction prostate motion during moderately hypofractionated radiotherapy

7Citations
N/AReaders
Get full text

Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Sumida, I., Yamaguchi, H., Das, I. J., Anetai, Y., Kizaki, H., Aboshi, K., … Ogawa, K. (2017). Robust plan optimization using edgeenhanced intensity for intrafraction organ deformation in prostate intensity-modulated radiation therapy. PLoS ONE, 12(3). https://doi.org/10.1371/journal.pone.0173643

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

50%

Researcher 2

33%

Professor / Associate Prof. 1

17%

Readers' Discipline

Tooltip

Medicine and Dentistry 4

50%

Computer Science 2

25%

Nursing and Health Professions 1

13%

Neuroscience 1

13%

Article Metrics

Tooltip
Mentions
News Mentions: 1

Save time finding and organizing research with Mendeley

Sign up for free