Simultaneous electrochemical sensing of dihydroxy benzene isomers at cost-effective allura red polymeric film modified glassy carbon electrode

16Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

Background: A simple and simultaneous electrochemical sensing platform was fabricated by electropolymerization of allura red on glassy carbon electrode (GCE) for the interference-free detection of dihydroxy benzene isomers. Methods: The modified working electrode was characterized by electrochemical and field emission scanning electron microscopy methods. The modified electrode showed excellent electrocatalytic activity for the electrooxidation of catechol (CC) and hydroquinone (HQ) at physiological pH of 7.4 by cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques. Results: The effective split in the overlapped oxidation signal of CC and HQ was achieved in a binary mixture with peak to peak separation of 0.102 V and 0.103 V by CV and DPV techniques. The electrode kinetics was found to be adsorption-controlled. The oxidation potential directly depends on the pH of the buffer solution, and it witnessed the transfer of equal number of protons and electrons in the redox phenomenon. Conclusions: The limit of detection (LOD) for CC and HQ was calculated to be 0.126 μM and 0.132 μM in the linear range of 0 to 80.0 μM and 0 to 110.0 μM, respectively, by ultra-sensitive DPV technique. The practical applicability of the proposed sensor was evaluated for tap water sample analysis, and good recovery rates were observed. Graphical abstract: Electrocatalytic interaction of ALR/GCE with dihydroxy benzene isomers.[Figure not available: see fulltext.]

References Powered by Scopus

Removal of basic dye Auramine-O by ZnS:Cu nanoparticles loaded on activated carbon: Optimization of parameters using response surface methodology with central composite design

687Citations
N/AReaders
Get full text

Modeling of competitive ultrasonic assisted removal of the dyes - Methylene blue and Safranin-O using Fe<inf>3</inf>O<inf>4</inf> nanoparticles

610Citations
N/AReaders
Get full text

ZnO/Ag/CdO nanocomposite for visible light-induced photocatalytic degradation of industrial textile effluents

601Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Square wave voltammetric determination of quercetin in wine and fruit juice samples at poly (safranine O) modified glassy carbon electrode

27Citations
N/AReaders
Get full text

Carbon-Based Materials and Their Applications in Sensing by Electrochemical Voltammetry

24Citations
N/AReaders
Get full text

An experimental and theoretical approach to electrochemical sensing of environmentally hazardous dihydroxy benzene isomers at polysorbate modified carbon paste electrode

22Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ganesh, P. S., Shimoga, G., Lee, S. H., Kim, S. Y., & Ebenso, E. E. (2021). Simultaneous electrochemical sensing of dihydroxy benzene isomers at cost-effective allura red polymeric film modified glassy carbon electrode. Journal of Analytical Science and Technology, 12(1). https://doi.org/10.1186/s40543-021-00270-w

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

50%

Lecturer / Post doc 1

25%

Researcher 1

25%

Readers' Discipline

Tooltip

Chemistry 4

57%

Agricultural and Biological Sciences 2

29%

Environmental Science 1

14%

Save time finding and organizing research with Mendeley

Sign up for free