Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation

  • Perez M
  • Mahaffey K
  • Hedlin H
  • et al.
1.2kCitations
Citations of this article
1.6kReaders
Mendeley users who have this article in their library.

Abstract

BACKGROUND Optical sensors on wearable devices can detect irregular pulses. The ability of a smartwatch application (app) to identify atrial fibrillation during typical use is unknown. METHODS Participants without atrial fibrillation (as reported by the participants themselves) used a smartphone (Apple iPhone) app to consent to monitoring. If a smartwatch-based irregular pulse notification algorithm identified possible atrial fibrillation, a telemedicine visit was initiated and an electrocardiography (ECG) patch was mailed to the participant, to be worn for up to 7 days. Surveys were administered 90 days after notification of the irregular pulse and at the end of the study. The main objectives were to estimate the proportion of notified participants with atrial fibrillation shown on an ECG patch and the positive predictive value of irregular pulse intervals with a targeted confidence interval width of 0.10. RESULTS We recruited 419,297 participants over 8 months. Over a median of 117 days of monitoring, 2161 participants (0.52%) received notifications of irregular pulse. Among the 450 participants who returned ECG patches containing data that could be analyzed - which had been applied, on average, 13 days after notification - atrial fibrillation was present in 34% (97.5% confidence interval [CI], 29 to 39) overall and in 35% (97.5% CI, 27 to 43) of participants 65 years of age or older. Among participants who were notified of an irregular pulse, the positive predictive value was 0.84 (95% CI, 0.76 to 0.92) for observing atrial fibrillation on the ECG simultaneously with a subsequent irregular pulse notification and 0.71 (97.5% CI, 0.69 to 0.74) for observing atrial fibrillation on the ECG simultaneously with a subsequent irregular tachogram. Of 1376 notified participants who returned a 90-day survey, 57% contacted health care providers outside the study. There were no reports of serious app-related adverse events. CONCLUSIONS The probability of receiving an irregular pulse notification was low. Among participants who received notification of an irregular pulse, 34% had atrial fibrillation on subsequent ECG patch readings and 84% of notifications were concordant with atrial fibrillation. This siteless (no on-site visits were required for the participants), pragmatic study design provides a foundation for large-scale pragmatic studies in which outcomes or adherence can be reliably assessed with user-owned devices. (Funded by Apple; Apple Heart Study ClinicalTrials.gov number, NCT03335800.).

References Powered by Scopus

Atrial fibrillation as an independent risk factor for stroke: The framingham study

6360Citations
N/AReaders
Get full text

Subclinical atrial fibrillation and the risk of stroke

1740Citations
N/AReaders
Get full text

Cryptogenic stroke and underlying atrial fibrillation

1700Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Heart Disease and Stroke Statistics-2022 Update: A Report from the American Heart Association

3871Citations
N/AReaders
Get full text

Heart Disease and Stroke Statistics - 2023 Update: A Report from the American Heart Association

2596Citations
N/AReaders
Get full text

Epidemiology of Atrial Fibrillation in the 21st Century: Novel Methods and New Insights

927Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., … Turakhia, M. P. (2019). Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation. New England Journal of Medicine, 381(20), 1909–1917. https://doi.org/10.1056/nejmoa1901183

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 394

57%

Researcher 185

27%

Professor / Associate Prof. 87

13%

Lecturer / Post doc 25

4%

Readers' Discipline

Tooltip

Medicine and Dentistry 437

67%

Engineering 102

16%

Computer Science 61

9%

Nursing and Health Professions 55

8%

Article Metrics

Tooltip
Mentions
Blog Mentions: 12
News Mentions: 143
References: 1
Social Media
Shares, Likes & Comments: 67

Save time finding and organizing research with Mendeley

Sign up for free