Evaluation of local radiation damage in silicon sensor via charge collection mapping with the Timepix read-out chip

2Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

Studies of radiation hardness of silicon sensors are standardly performed with single-pad detectors evaluating their global electrical properties. In this work we introduce a technique to visualize and determine the spatial distribution of radiation damage across the area of a semiconductor sensor. The sensor properties such as charge collection efficiency and charge diffusion were evaluated locally at many points of the sensor creating 2D maps. For this purpose we used a silicon sensor bump bonded to the pixelated Timepix read-out chip. This device, operated in Time-over-threshold (TOT) mode, allows for the direct energy measurement in each pixel. Selected regions of the sensor were intentionally damaged by defined doses (up to 1012 particles/cm 2) of energetic protons (of 2.5 and 4 MeV). The extent of the damage was measured in terms of the detector response to the same ions. This procedure was performed either on-line during irradiation or off-line after it. The response of the detector to each single particle was analyzed determining the charge collection efficiency and lateral charge diffusion. We evaluated the changes of these parameters as a function of radiation dose. These features are related to the local properties such as the spatial homogeneity of the sensor. The effect of radiation damage was also independently investigated measuring local changes of signal response to γ, and X rays and alpha particles. © 2013 IOP Publishing Ltd and Sissa Medialab srl.

References Powered by Scopus

Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements

895Citations
N/AReaders
Get full text

Precise energy calibration of pixel detector working in time-over-threshold mode

239Citations
N/AReaders
Get full text

Pixelman: A multi-platform data acquisition and processing software package for Medipix2, Timepix and Medipix3 detectors

181Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The SATRAM Timepix spacecraft payload in open space on board the Proba-V satellite for wide range radiation monitoring in LEO orbit

74Citations
N/AReaders
Get full text

VZLUSAT-1: Verification of new materials and technologies for space

10Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Platkevic, M., Jakubek, J., Havranek, V., Jakubek, M., Pospisil, S., Semian, V., & Zemlicka, J. (2013). Evaluation of local radiation damage in silicon sensor via charge collection mapping with the Timepix read-out chip. In Journal of Instrumentation (Vol. 8). https://doi.org/10.1088/1748-0221/8/04/C04001

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

75%

Researcher 2

25%

Readers' Discipline

Tooltip

Physics and Astronomy 8

100%

Save time finding and organizing research with Mendeley

Sign up for free