Appropriate iMAR presets for metal artifact reduction from surgical clips and titanium burr hole covers on postoperative non-contrast brain CT

7Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To evaluate suitable iterative metal artifact reduction (iMAR) presets for titanium neurosurgical clips and burr hole covers (BHCs) on postoperative non-contrast computed tomography (NCCT). Method: Twenty-two patients who underwent NCCT after intracranial aneurysmal clipping were included. NCCT images were postprocessed using eight currently available iMAR presets. In each image, a circular region of interest (ROI) was placed around clip, BHC, and on parietal lobe as reference. Standard deviation (SD) and attenuation value (HU) were measured in each ROI to obtain artifact index (AI) and contrast-to-noise ratio (CNR). For each iMAR preset, SD, AI, HU, and CNR were compared with those without iMAR for clips and BHCs. Visual assessment around each clip and BHC was performed by two neuroradiologists using three-point visual score (VS) (1 = no apparent, 2 = minor, and 3 = severe artifacts). Results: Among the presets, the neuro-coils preset (iMAR-NC) showed the lowest SD, AI, and VS for clips (P < 0.001). For BHCs, HU, CNR, and VS with iMAR-NC were significantly higher than those without iMAR (P < 0.001). SD, AI, and VS with the shoulder implants preset (iMAR-ShI) were significantly lower than those without iMAR for clips (P = 0.002, 0.002, and P < 0.001, respectively). For BHCs, VS with iMAR-ShI was lowest among the presets (P = 0.004). Conclusions: Although iMAR-NC reduces metal artifacts from clips, it strengthens artifacts from BHCs. For postoperative NCCT, iMAR-ShI most effectively reduces metal artifacts from both clips and BHCs in a single preset.

References Powered by Scopus

Unruptured intracranial aneurysms: Natural history, clinical outcome, and risks of surgical and endovascular treatment

3243Citations
N/AReaders
Get full text

Normalized metal artifact reduction (NMAR) in computed tomography

499Citations
N/AReaders
Get full text

Guidelines for the management of aneurysmal subarachnoid hemorrhage: A statement for healthcare professionals from a special writing group of the stroke council, american heart association

446Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Iterative Metal Artifact Reduction in Head and Neck CT Facilitates Tumor Visualization of Oral and Oropharyngeal Cancer Obscured by Artifacts From Dental Hardware

6Citations
N/AReaders
Get full text

A nonlinear scaling-based normalized metal artifact reduction to reduce low-frequency artifacts in energy-integrating and photon-counting CT

5Citations
N/AReaders
Get full text

A New Iterative Metal Artifact Reduction Algorithm for Both Energy-Integrating and Photon-Counting CT Systems

4Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Shinohara, Y., Ohmura, T., Sasaki, F., Inomata, T., Itoh, T., & Kinoshita, T. (2021). Appropriate iMAR presets for metal artifact reduction from surgical clips and titanium burr hole covers on postoperative non-contrast brain CT. European Journal of Radiology, 141. https://doi.org/10.1016/j.ejrad.2021.109811