Expanding on the relationship between continuing current and in-cloud leader growth

11Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

When lightning connects to the ground, there is a large surge of current, called the return stroke, which is occasionally followed by a longer-lasting steady current, called continuing current (CC). In a previous study of negative cloud-to-ground (-CG) flashes, we observed the growth rate of in-cloud positive leaders in an attempt to identify occurrences of CC. However, there was no observed change in positive leader growth rate during CC of negative CG flashes. In this study, we use the Langmuir Electric Field Array, Lightning Mapping Array, and Flash-Continuous Broadband Digital Interferometer data to extend the previous study to the growth of the negative leader during positive CG flashes. We have found that in contrast with previous results, negative leader growth during positive CG flashes does show increases in growth rates coincident with CC. Finally, we find that the growth rate magnitudes for positive and negative leaders are typically ~2-4 km/10 ms and ~25-40 km/10 ms, respectively. These contrasting results highlight the differences between positive and negative leaders and provide strong evidence as to why -CC and +CC behave differently. Negative leaders inject higher amounts of current and allow the channel to remain conductive throughout the duration of CC. Whereas for positive leaders, the channel becomes nonconductive relatively quickly. It is therefore disconnected from the channel to the ground, and, due to the positive leader’s continued growth, an electric potential is built up until a K event is produced that re-ionizes the channel. Plain Language Summary Cloud-to-ground (CG) discharges are bipolar events consisting of a downward leader to ground fed by an opposite polarity leader within the cloud. For negative CG discharges (-CGs), the downward leader lowers negative charge toward ground, while the associated in-cloud breakdown is positive. The opposite is true of positive CG discharges (+CGs). When the descending leader contacts the ground, ground potential propagates rapidly back up the channel as a high-current return stroke, which can occasionally initiate a long-lasting continuous current (CC). Generally, -CG flashes consist of three to five return strokes, whereas +CG flashes consist of one. In this study, we analyze the growth of negative leaders of +CG flashes during CC to determine whether there is any observable change. We have found that in contrast with -CG flashes, negative leader growth during +CG flashes does show increases in growth rates coincident with CC. Furthermore, we find that negative leaders inject higher amounts of current and allow the channel to remain conductive throughout the duration of CC. Whereas for positive leaders, which inject smaller amounts of current, the channel becomes nonconductive relatively quickly, which leads to multiple return strokes.

References Powered by Scopus

A GPS-based three-dimensional lightning mapping system: Initial observations in central New Mexico

634Citations
N/AReaders
Get full text

An overview of lightning locating systems: History, techniques, and data uses, with an in-depth look at the U.S. NLDN

580Citations
N/AReaders
Get full text

An omnibus test of normality for moderate and large size samples

422Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Variation of lightning-ignited wildfire patterns under climate change

46Citations
N/AReaders
Get full text

Relationship Between Sprite Current and Morphology

10Citations
N/AReaders
Get full text

Multi-Stroke Positive Cloud-To-Ground Lightning Sharing the Same Channel Observed With a VHF Broadband Interferometer

9Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lapierre, J. L., Sonnenfeld, R. G., Stock, M., Krehbiel, P. R., Edens, H. E., & Jensen, D. (2017). Expanding on the relationship between continuing current and in-cloud leader growth. Journal of Geophysical Research, 122(8), 4150–4164. https://doi.org/10.1002/2016JD026189

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

60%

Researcher 4

40%

Readers' Discipline

Tooltip

Earth and Planetary Sciences 6

60%

Engineering 2

20%

Computer Science 1

10%

Physics and Astronomy 1

10%

Save time finding and organizing research with Mendeley

Sign up for free