Real-time, smartphone-based processing of lateral flow assays for early failure detection and rapid testing workflows

11Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

Despite their simplicity, lateral flow immunoassays (LFIAs) remain a crucial weapon in the diagnostic arsenal, particularly at the point-of-need. However, methods for analysing LFIAs still rely heavily on suboptimal human readout and rudimentary end-point analysis. This negatively impacts both testing accuracy and testing times, ultimately lowering diagnostic throughput. Herein, we present an automated computational imaging method for processing and analysing multiple LFIAs in real-time and in parallel. This method relies on the automated detection of signal intensity at the test line, control line, and background, and employs statistical comparison of these values to predictively categorise tests as "positive", "negative", or "failed". We show that such a computational methodology can be transferred to a smartphone and detail how real-time analysis of LFIAs can be leveraged to decrease the time-to-result and increase testing throughput. We compare our method to naked-eye readout and demonstrate a shorter time-to-result across a range of target antigen concentrations and fewer false negatives compared to human subjects at low antigen concentrations.

References Powered by Scopus

Lateral flow assays: Principles, designs and labels

505Citations
N/AReaders
Get full text

Evaluation of rapid antigen test for detection of SARS-CoV-2 virus

383Citations
N/AReaders
Get full text

Taking connected mobile-health diagnostics of infectious diseases to the field

243Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Lateral Flow Assay: A Summary of Recent Progress for Improving Assay Performance

41Citations
N/AReaders
Get full text

Paper-Based Laser-Pyrolyzed Electrofluidics: An Electrochemical Platform for Capillary-Driven Diagnostic Bioassays

29Citations
N/AReaders
Get full text

Smartphone Imaging Flow Cytometry for High-Throughput Single-Cell Analysis

8Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Colombo, M., Bezinge, L., Tapia, A. R., Shih, C. J., De Mello, A. J., & Richards, D. A. (2023). Real-time, smartphone-based processing of lateral flow assays for early failure detection and rapid testing workflows. Sensors and Diagnostics, 2(1), 100–110. https://doi.org/10.1039/d2sd00197g

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

67%

Researcher 4

33%

Readers' Discipline

Tooltip

Chemistry 3

38%

Engineering 3

38%

Chemical Engineering 1

13%

Materials Science 1

13%

Save time finding and organizing research with Mendeley

Sign up for free