Comparison of Rapid Centrifugation Technique with Conventional Centrifugation for Prothrombin Time (PT) and Activated Partial Thromboplastin Time (APTT) Testing

4Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Prothrombin Time (PT) and activated partial thromboplastin time (APTT) are frequently performed coagulation tests in patients with coagulation disorders especially in critical care areas and in monitoring patients on anticoagulation therapy. In coagulation testing, sample processing especially centrifugation is one of the most critical steps that affect turnaround time (TAT). This study was carried out over a period of 1 year. Three hundred paired samples from patients sent for PT and APTT estimation were included. One sample was centrifuged in a regular bench top centrifuge at 1500g for 20 min. The other sample was divided into two polypropylene aliquots and centrifuged in a microcentrifuge at 13000g for 3 min. The plasma obtained from both methods was tested for PT and APTT using the automated method on STA Compact coagulometer (Stago) using commercial thromboplastin STA R -Neoplastine R C1 Plus and phospholipid (cephalin), STA R -C K PREST R 5 respectively. Data were analyzed using descriptive statistics, Student t test, correlation coefficient and Bland–Altman plots. Mean PT, INR and APTT for both centrifugation methods was comparable with no statistically significant difference (p > 0.05). PT, INR and APTT also showed good correlation (r > 0.98) when compared between the two methods of centrifugation. Bland–Altman comparison between rapid and conventional methods of centrifugation for PT, INR and APTT also showed acceptable agreement. Rapid centrifugation technique for routine coagulation testing can be used safely with a significant reduction in the TAT. This can benefit patients in critical care settings and those on outpatient oral anticoagulant therapy.

References Powered by Scopus

Quality standards for sample collection in coagulation testing

167Citations
N/AReaders
Get full text

Pre-analytical issues in the haemostasis laboratory: Guidance for the clinical laboratories

112Citations
N/AReaders
Get full text

Physician satisfaction and emergency department laboratory test turnaround time: Observations based on College of American Pathologists Q-Probes studies

109Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Hematology and coagulation preanalytics for clinical chemists: Factors intrinsic to the sample and extrinsic to the patient

3Citations
N/AReaders
Get full text

Genetic Polymorphisms Associated with Prothrombin Time and Activated Partial Thromboplastin Time in Chinese Healthy Population

1Citations
N/AReaders
Get full text

Effect of Rapid Centrifugation Using High Centrifugal Force on Procoagulant Activity in Plasma Samples

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Chandler, E., Kakkar, N., & Kaur, R. (2019). Comparison of Rapid Centrifugation Technique with Conventional Centrifugation for Prothrombin Time (PT) and Activated Partial Thromboplastin Time (APTT) Testing. Indian Journal of Hematology and Blood Transfusion, 35(1), 161–166. https://doi.org/10.1007/s12288-018-0983-4

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

83%

Lecturer / Post doc 1

17%

Readers' Discipline

Tooltip

Medicine and Dentistry 3

38%

Biochemistry, Genetics and Molecular Bi... 3

38%

Chemical Engineering 1

13%

Pharmacology, Toxicology and Pharmaceut... 1

13%

Save time finding and organizing research with Mendeley

Sign up for free