High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging

11Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background/Aim: The turbo spin-echo (TSE) sequence is widely used for musculoskeletal (MSK) imaging; however, its acquisition speed is limited and can be easily affected by motion artifacts. We aimed to evaluate whether the use of a simultaneous multi-slice TSE (SMS-TSE) sequence can accelerate MSK imaging while maintaining image quality when compared with the routine TSE sequence. Methods: We prospectively enrolled 71 patients [mean age, 37.43 ± 12.56 (range, 20–67) years], including 37 men and 34 women, to undergo TSE and SMS sequences. The total scanning times for the wrist, ankle and knee joint with routine sequence were 14.92, 13.97, and 13.48 min, respectively. For the SMS-TSE sequence, they were 7.52, 7.20, and 6.87 min. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), were measured. Three experienced MSK imaging radiologists qualitatively evaluated the image quality of bone texture, cartilage, tendons, ligament, meniscus, and artifact using a 5-point evaluation system, and the diagnostic performance of the SMS-TSE sequences was evaluated. Results: Compared with the routine TSE sequences, the scanning time was lower by 49.60, 48.46, and 49.04% using SMS-TSE sequences for the wrist, ankle, and knee joints, respectively. For the SNR comparison, the SMS-TSE sequences were significantly higher than the routine TSE sequence for wrist (except for Axial-T2WI-FS), ankle, and knee joint MR imaging (all p < 0.05), but no statistical significance was obtained for the CNR measurement (all p > 0.05, except for Sag-PDWI-FS in ankle joint). For the wrist joint, the diagnostic sensitivity, specificity, and accuracy were 88.24, 100, and 92%. For the ankle joint, they were 100, 75, and 93.33%. For the knee joint, they were 87.50, 85.71, and 87.10%. Conclusion: The use of the SMS-TSE sequence in the wrist, ankle, and knee joints can significantly reduce the scanning time and show similar image quality when compared with the routine TSE sequence.

References Powered by Scopus

Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty

1000Citations
N/AReaders
Get full text

Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging

489Citations
N/AReaders
Get full text

Use of multicoil arrays for separation of signal from multiple slices simultaneously excited

448Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Pediatric magnetic resonance imaging: faster is better

19Citations
N/AReaders
Get full text

Deep Learning MRI Reconstruction for Accelerating Turbo Spin Echo Hand and Wrist Imaging: A Comparison of Image Quality, Visualization of Anatomy, and Detection of Common Pathologies with Standard Imaging

10Citations
N/AReaders
Get full text

Multi-level classification of knee cartilage lesion in multimodal MRI based on deep learning

7Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Gao, F., Wen, Z., Dou, S., Kan, X., Wei, S., & Ge, Y. (2021). High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging. Frontiers in Physiology, 12. https://doi.org/10.3389/fphys.2021.759888

Readers over time

‘22‘23‘2402468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

67%

Lecturer / Post doc 1

33%

Readers' Discipline

Tooltip

Medicine and Dentistry 3

75%

Nursing and Health Professions 1

25%

Save time finding and organizing research with Mendeley

Sign up for free
0