Aims: Thyroid volume has to be measured in goiters prior to radioiodine treatment to calculate the needed amount of radioactivity. Modern clinical equipment for ultrasonography shows the trend to smaller probes, so that larger goiters do not fit any longer into the probe's field of view. This study evaluated the feasibility and accuracy of stitching procedures applied to thyroid volumetric analysis performed using three-dimensional ultrasound (3D-US). Material and methods: Ad hoc thyroid phantoms of different shapes (regular, nodular, thickened isthmus) and volumes (ranging between 50 and 400 mL) were developed. In 15 such phantoms the left and right lobes were separately scanned, and the 3D-US datasets were then assembled (stitched) using predefined landmarks and dedicated software. Volumetric analysis was then assessed via a conventional ellipsoid model (em) and manual tracing (mt). The correlation of measured and reference volumes was determined using Pearson's correlation coefficients and Bland and Altman limits of agreement. Results: The results showed a high level of agreement (with correlation coefficients ranging from 0.974 to 0.999) for all shapes and volumes tested, including the largest volume of 400 mL. The mt method, although more time consuming, proved superior to the em. Conclusions: Stitching-mediated thyroid volumetric analysis is accurate, and its clinical performance should be investigated in future studies.

References Powered by Scopus

STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

42231Citations
N/AReaders
Get full text

Three-dimensional ultrasound: Accuracy of distance and volume measurements

245Citations
N/AReaders
Get full text

Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging

140Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Automated Segmentation of Thyroid Nodule, Gland, and Cystic Components from Ultrasound Images Using Deep Learning

73Citations
N/AReaders
Get full text

Ultrasound image segmentation through deep learning based improvised U-net

14Citations
N/AReaders
Get full text

Ultrasound cine loop standard operating procedure for benign thyroid diseases—evaluation of non-physician application

8Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Freesmeyer, M., Knichel, L., Kühnel, C., & Winkens, T. (2018). Stitching of sensor-navigated 3D ultrasound datasets for the determination of large thyroid volumes - a phantom study. Medical Ultrasonography, 20(4), 480–486. https://doi.org/10.11152/mu-1687

Readers over time

‘19‘20‘21‘22‘23‘2402468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

67%

Researcher 2

22%

Professor / Associate Prof. 1

11%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

67%

Engineering 2

22%

Sports and Recreations 1

11%

Save time finding and organizing research with Mendeley

Sign up for free
0