Comparing the consistency of electrocardiogram interval measurements by resting ECG versus 12-lead Holter

3Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In clinical trials, traditionally only a limited number of 12-lead resting electrocardiograms (ECGs) can be recorded and, thus, long intervals may elapse between assessment timepoints and valuable information may be missed during times when patients' cardiac electrical activity is not being monitored. These limitations have led to the increasing use of Holter recorders which provide continuous data registrations while reducing the burden on patients and freeing up time for clinical trial staff to perform other tasks. However, there is a shortage of data comparing the two approaches. In this study, data from a randomized, double-blind, four-period, crossover thorough QT study in 40 healthy subjects were used to compare continuous 12-lead Holter recordings to standard 12-lead resting ECGs which were recorded in parallel. Heart rate and QT interval data were estimated by averaging three consecutive heartbeats. Values exceeding the sample average by more than 5% were tagged as outliers and excluded from the analysis. Visual comparisons of the ECG waveforms of the Holter signal showed a good correlation with resting ECGs at matching timepoints. Resting ECG data revealed sex differences that Holter data did not show. Specifically, women were found to have a longer QTcF of 20 ms, while men had a lower heart rate. We found that continuous recordings provided a more accurate reflection of changes in cardiac electrical activity over 24 hr. However, manual adjudication is still required to ensure the quality and accuracy of ECG data, and that only artifacts are removed thereby avoiding loss of true signals.

References Powered by Scopus

Drug-Induced Prolongation of the QT Interval

1761Citations
N/AReaders
Get full text

The measurement of the QT interval

254Citations
N/AReaders
Get full text

Assessment of repolarization heterogeneity for prediction of mortality in cardiovascular disease: Peak to the end of the T wave interval and nondipolar repolarization components

127Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Deep residual-dense network based on bidirectional recurrent neural network for atrial fibrillation detection

21Citations
N/AReaders
Get full text

A High-Performance Low Complex Design and Implementation of QRS Detector Using Modi¯ed MaMeMi Filter Optimized with Mayfly Optimization Algorithm

6Citations
N/AReaders
Get full text

Predictive value of dynamic electrocardiography for myocardial ischemia and arrhythmia in patients with coronary heart disease

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Mendzelevski, B., Spencer, C. S., Freier, A., Camilleri, D., Graff, C., & Täubel, J. (2021). Comparing the consistency of electrocardiogram interval measurements by resting ECG versus 12-lead Holter. Annals of Noninvasive Electrocardiology, 26(5). https://doi.org/10.1111/anec.12851

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

75%

Researcher 2

25%

Readers' Discipline

Tooltip

Medicine and Dentistry 4

50%

Engineering 2

25%

Nursing and Health Professions 1

13%

Sports and Recreations 1

13%