An integrated optimal operating strategy for a grid-connected AC microgrid under load and renewable generation uncertainty considering demand response

66Citations
Citations of this article
59Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The challenge of a modern energy system is to be reliable, robust, easily accessible, economically viable, and environment-friendly. This paper addresses the above issue by proposing a novel integrated optimal energy management scheme for a grid-connected AC microgrid. The objectives of the energy management scheme are to minimize the cost of operation and reduce the emission. A group of measures like incentive-based demand response (DR) program economic-emission load dispatch, optimal battery scheduling, and network reconfiguration is simultaneously implemented in the energy management scheme to enhance the steady-state performance of the microgrid. Uncertainties are modeled using a stochastic approach in this work. The bi-objective optimization is carried out in the fuzzy domain employing the “fuzzy max–min” satisfaction criterion. Further, the incentive value of the DR program is optimized, and a sensitivity analysis is carried out to investigate the impact of the incentive value on the operating cost. Simulation studies on a thirty-three node test system demonstrate that the operating cost can be reduced by 18.90%, and emission by 45.44% for the given test system. If both cost and emission are to be reduced simultaneously, then the operating cost and emission are reduced by 9.08% and 34.85%, respectively.

References Powered by Scopus

Fuzzy Logic with Engineering Applications: Third Edition

3405Citations
1706Readers
Get full text

Microgrid: A conceptual solution

1746Citations
892Readers
Get full text
1274Citations
714Readers
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Nayak, A., Maulik, A., & Das, D. (2021). An integrated optimal operating strategy for a grid-connected AC microgrid under load and renewable generation uncertainty considering demand response. Sustainable Energy Technologies and Assessments, 45. https://doi.org/10.1016/j.seta.2021.101169

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 16

59%

Researcher 5

19%

Professor / Associate Prof. 3

11%

Lecturer / Post doc 3

11%

Readers' Discipline

Tooltip

Engineering 20

77%

Energy 4

15%

Social Sciences 1

4%

Agricultural and Biological Sciences 1

4%

Save time finding and organizing research with Mendeley

Sign up for free