This study estimates diagnostic performance of late-night salivary cortisol (LNSC) as measured by automated electrochemiluminescence immunoassay (ECLIA), evaluates the clinical implication of two consecutive LNSC measurements, and compares its accuracy with enzyme-linked immunosorbent assay (ELISA) and serum cortisol after low-dose dexamethasone suppression test (DST) in obese and overweight patients referred for suspected Cushing's syndrome (CS). One hundred twenty three consecutive obese and overweight referred patients and 98 healthy volunteers provided two saliva samples collected at 23:00 using a Salivette (Sarstedt, Germany), assayed by ECLIA (Cobas e601) and ELISA. The patients underwent DST and were further evaluated until CS was pathologically confirmed (n = 45) or excluded. Diagnostic performance of LNSC was evaluated by receiver operating characteristic (ROC) analysis. The total areas under the curve (AUC) were calculated to compare the different tests. We found that a cut-off value of 9.4 nmol/l can differentiate CS among obese and overweight patients with sensitivity of 84.4 % (95% CI 71.2-92.2), specificity of 92.3 % (95% CI 84.2-96.4), and diagnostic odds ratio of 65.1 (95% CI 20.4-207.6). No difference was found between AUCs from the first, second, and the mean from the two LNSC measurements (ECLIA), LNSC (ELISA), or DST. The single LNSC (ECLIA) and DST improved the sensitivity and specificity for concordant results up to 100 and 97.4 %, respectively. In conclusion, due to its automation and its comparable diagnostic performance, ECLIA is preferable as a first-line LNSC screening test for CS. The initial use of single LNSC followed by DST provides better diagnostic performance for concordant results. © Springer Science+Business Media, LLC 2012.

References Powered by Scopus

The meaning and use of the area under a receiver operating characteristic (ROC) curve

17930Citations
N/AReaders
Get full text

A method of comparing the areas under receiver operating characteristic curves derived from the same cases

6361Citations
N/AReaders
Get full text

The diagnosis of Cushing's syndrome: An endocrine society clinical practice guideline

2088Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Recent advances in cortisol sensing technologies for point-of-care application

268Citations
N/AReaders
Get full text

Accuracy of laboratory tests for the diagnosis of cushing syndrome

67Citations
N/AReaders
Get full text

Pathogenesis of hepatic steatosis: The link between hypercortisolism and non-alcoholic fatty liver disease

65Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Belaya, Z. E., Iljin, A. V., Melnichenko, G. A., Rozhinskaya, L. Y., Dragunova, N. V., Dzeranova, L. K., … Dedov, I. I. (2012). Diagnostic performance of late-night salivary cortisol measured by automated electrochemiluminescence immunoassay in obese and overweight patients referred to exclude Cushing’s syndrome. Endocrine, 41(3), 494–500. https://doi.org/10.1007/s12020-012-9658-3

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 16

55%

Researcher 8

28%

Professor / Associate Prof. 3

10%

Lecturer / Post doc 2

7%

Readers' Discipline

Tooltip

Medicine and Dentistry 18

62%

Agricultural and Biological Sciences 4

14%

Biochemistry, Genetics and Molecular Bi... 4

14%

Veterinary Science and Veterinary Medic... 3

10%

Save time finding and organizing research with Mendeley

Sign up for free