Evaluating the performance of lateral flow devices for total aflatoxins with special emphasis on their robustness under sub-saharan conditions

7Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

As aflatoxins are a global risk for humans and animals, testing methods for rapid on-site screening are increasingly needed alongside the standard analytical laboratory tools. In the presented study, lateral flow devices (LFDs) for rapid total aflatoxin screening were thoroughly investigated with respect to their matrix effects, cross-reactivity, their performance under harsh conditions in Sub-Saharan Africa (SSA), and their stability, as well as when compared with liquid chromatography-tandem mass spectrometry (LC-MS/MS). To analyze the matrix effects, qualitative test kits offering a certain cutoff level were used to screen different nut samples. In addition, these tests were challenged on their cross-reactivity with 230 fungal toxins and metabolites. Furthermore, the resulting measurements performed under harsh tropical conditions (up to 38.4◦C and 91% relative humidity) in SSA, specifically Burkina Faso and Mozambique, were compared with the results from a well-established and validated LC-MS/MS-based reference method. The comparison of the on-site LFD results with the reference method showed a good agreement: 86.4% agreement, 11.8% non-agreement, and 1.8% invalid test results. To test the robustness of the cutoff tests, short-and long-term stability testing was carried out in Mozambique and Nigeria. For both experiments, no loss of test performance could be determined. Finally, a subset of African corn samples was shipped to Austria and analyzed under laboratory conditions using semiquantitative aflatoxin tests. A good correlation was found between the rapid strip tests and the LC-MS/MS reference method. Overall, the evaluated LFDs showed satisfying results regarding their cross-reactivity, matrix effects, stability, and robustness.

References Powered by Scopus

Mycotoxins

3075Citations
N/AReaders
Get full text

Mechanisms of aflatoxin carcinogenesis

735Citations
N/AReaders
Get full text

Aflatoxin contamination of commercial maize products during an outbreak of acute aflatoxicosis in eastern and central Kenya

569Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Verification of the Accuscan gold reader and RIDA smart phone application rapid test kits in detection and quantification of aflatoxin levels in maize from selected regions in Kenya

19Citations
N/AReaders
Get full text

Latest Advances in Arbovirus Diagnostics

11Citations
N/AReaders
Get full text

Developments in mycotoxin analysis: an update for 2021-22

6Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Cvak, B., Warth, B., Atehnkeng, J., Parich, A., Moritz, A., Sulyok, M., & Krska, R. (2021). Evaluating the performance of lateral flow devices for total aflatoxins with special emphasis on their robustness under sub-saharan conditions. Toxins, 13(11). https://doi.org/10.3390/toxins13110742

Readers over time

‘21‘22‘23‘24‘25036912

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 6

43%

Researcher 5

36%

Professor / Associate Prof. 3

21%

Readers' Discipline

Tooltip

Agricultural and Biological Sciences 6

67%

Materials Science 1

11%

Pharmacology, Toxicology and Pharmaceut... 1

11%

Social Sciences 1

11%

Article Metrics

Tooltip
Mentions
Blog Mentions: 1
Social Media
Shares, Likes & Comments: 113

Save time finding and organizing research with Mendeley

Sign up for free
0