Results from a real-time dosimetry study during left atrial ablations performed with ultra-low dose radiation settings

2Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Three-dimensional mapping systems and the use of ultra-low dose radiation protocols have supported minimization of radiation dose during left atrial ablation procedures. By using optimal shielding, scattered radiation reaching the operator can be further reduced. This prospective study was designed to determine the remaining operator radiation exposure during left atrial catheter ablations using real-time dosimetry. Methods: Radiation dose was recorded using real-time digital dosimetry badges outside the lead apron during 201 consecutive left atrial fibrillation ablation procedures. All procedures were performed using the same X‑ray system (Siemens Healthineers Artis dBc; Siemens Healthcare AG, Erlangen, Germany) programmed with ultra-low dose radiation settings including a low frame rate (two frames per second), maximum copper filtration, and an optimized detector dose. To reduce scattered radiation to the operators, table-suspended lead curtains, ceiling-suspended leaded plastic shields, and radiation-absorbing shields on the patient were positioned in an overlapping configuration. Results: The 201 procedures included 139 (69%) pulmonary vein isolations (PVI) (20 cryoballoon ablations, 119 radiofrequency ablations, with 35 cases receiving additional ablation of the cavotricuspid isthmus) and 62 (31%) PVI plus further left atrial substrate ablation. Mean radiation dose measured as dose area product for all procedures was 128.09 ± 187.87 cGy ∙ cm2 with a mean fluoroscopy duration of 9.4 ± 8.7 min. Real-time dosimetry showed very low average operator doses of 0.52 ± 0.10 µSv. A subanalysis of 51 (25%) procedures showed that the radiation burden for the operator was highest during pulmonary vein angiography. Conclusion: The use of ultra-low dose radiation protocols in combination with optimized shielding results in extremely low scattered radiation reaching the operator.

References Powered by Scopus

Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological procedures

261Citations
N/AReaders
Get full text

Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping

177Citations
N/AReaders
Get full text

The radiation issue in cardiology: The time for action is now

131Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Practical guidance to reduce radiation exposure in electrophysiology applying ultra low-dose protocols: a European Heart Rhythm Association review

19Citations
N/AReaders
Get full text

Reasons for gender inequities in invasive electrophysiology: A survey on family issues and career paths of female and male electrophysiology fellows in Germany

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Schreiber, T., Kähler, N., Biewener, S., Tscholl, V., Nagel, P., Attanasio, P., … Huemer, M. (2021). Results from a real-time dosimetry study during left atrial ablations performed with ultra-low dose radiation settings. Herzschrittmachertherapie Und Elektrophysiologie, 32(2), 244–249. https://doi.org/10.1007/s00399-021-00762-7

Readers over time

‘21‘22‘23‘24‘2500.751.52.253

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

100%

Readers' Discipline

Tooltip

Nursing and Health Professions 2

67%

Medicine and Dentistry 1

33%

Save time finding and organizing research with Mendeley

Sign up for free
0