Reliability of synthetic brain MRI for assessment of ischemic stroke with phantom validation of a relaxation time determination method

9Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

The reliability of relaxation time measures in synthetic magnetic resonance images (MRIs) of homemade phantoms were validated, and the diagnostic suitability of synthetic imaging was compared to that of conventional MRIs for detecting ischemic lesions. Phantoms filled with aqueous cupric-sulfate (CuSO4 ) were designed to mimic spin-lattice (T1 ) and spin-spin (T2 ) relaxation properties and were used to compare their accuracies and stabilities between synthetic and conventional scans of various brain tissues. To validate the accuracy of synthetic imaging in ischemic stroke diagnoses, the synthetic and clinical scans of 18 patients with ischemic stroke were compared, and the quantitative contrast-to-noise ratios (CNRs) were measured, using the Friedman test to determine significance in differences. Results using the phantoms showed no significant differences in the interday and intersession synthetic quantitative T1 and T2 values. However, between synthetic and referenced T1 and T2 values, differences were larger for longer relaxation times, showing that image intensities in synthetic scans are relatively inaccurate in the cerebrospinal fluid (CSF). Similarly, CNRs in CSF regions of stroke patients were significantly different on synthetic T2-weighted and T2-fluid-attenuated inversion recovery images. In contrast, differences in stroke lesions were insignificant between the two. Therefore, interday and intersession synthetic T1 and T2 values are highly reliable, and discrepancies in synthetic T1 and T2 relaxation times and image contrasts in CSF regions do not affect stroke lesion diagnoses. Additionally, quantitative relaxation times from synthetic images allow better estimations of ischemic stroke onset time, consequently increasing confidence in synthetic MRIs as diagnostic tools for ischemic stroke.

References Powered by Scopus

Automated anatomical labeling of activations in SPM using a macroscopic anatomical parcellation of the MNI MRI single-subject brain

13437Citations
N/AReaders
Get full text

Unbiased average age-appropriate atlases for pediatric studies

1588Citations
N/AReaders
Get full text

Determining the longitudinal relaxation time (T<inf>1</inf>) of blood at 3.0 tesla

583Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Brain Tumor Segmentation and Classification from Sensor-Based Portable Microwave Brain Imaging System Using Lightweight Deep Learning Models

21Citations
N/AReaders
Get full text

Application of MAGnetic resonance imaging compilation in acute ischemic stroke

9Citations
N/AReaders
Get full text

Sensor-based microwave brain imaging system (SMBIS): An experimental six-layered tissue based human head phantom model for brain tumor diagnosis using electromagnetic signals

8Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Li, C. W., Hsu, A. L., Huang, C. W. C., Yang, S. H., Lin, C. Y., Shieh, C. C., & Chan, W. P. (2020). Reliability of synthetic brain MRI for assessment of ischemic stroke with phantom validation of a relaxation time determination method. Journal of Clinical Medicine, 9(6), 1–11. https://doi.org/10.3390/jcm9061857

Readers over time

‘20‘21‘22‘23‘24‘2502468

Readers' Seniority