Time-in-range derived from self-measured blood glucose in people with type 2 diabetes advancing to iGlarLixi: A participant-level pooled analysis of three phase 3 LixiLan randomized controlled trials

1Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Aim: To evaluate the efficacy of a fixed-ratio combination of insulin glargine 100 U/mL plus lixisenatide (iGlarLixi) in people with type 2 diabetes (T2D) using derived time-in-range (dTIR). Methods: Participant-level data from LixiLan-L, LixiLan-O and LixiLan-G were pooled and dTIR (70-180 mg/dL), derived time-above-range (> 180 mg/dL) and derived time-below-range (dTBR; < 70 mg/dL) were calculated from participant seven-point self-monitored blood glucose profiles. Results: This pooled analysis included data from 2420 participants receiving iGlarLixi (n = 1093), iGlar (n = 836), Lixi (n = 234) or a glucagon-like peptide-1 receptor agonist (GLP-1 RA) (n = 257). Numerically greater improvements in least square (LS) means dTIR were seen from baseline to end of treatment (EOT) with iGlarLixi (25.7%) versus iGlar (15.8%), Lixi (11.7%) or GLP-1 RA (16.2%). At EOT, the mean (standard deviation) dTBR was 0.71% ± 3.4%, 0.61% ± 3.2%, 0.08% ± 1.0% and 0.0% ± 0.0% for iGlarLixi, iGlar, Lixi and GLP-1 RA, respectively. In a subgroup analysis, participants aged younger than 65 years (n = 1690) and 65 years or older (n = 713) showed numerically greater improvements in LS means dTIR from baseline to EOT with iGlarLixi versus iGlar, Lixi or GLP-1 RA. Conclusions: iGlarLixi achieved improvements in dTIR, with low dTBR values, providing further evidence to inform clinical outcomes with the use of iGlarLixi.

References Powered by Scopus

World Medical Association declaration of Helsinki: Ethical principles for medical research involving human subjects

0
20388Citations
N/AReaders
Get full text

Clinical targets for continuous glucose monitoring data interpretation: Recommendations from the international consensus on time in range

2667Citations
N/AReaders
Get full text

International consensus on use of continuous glucose monitoring

1581Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Time in range—A new gold standard in type 2 diabetes research?

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Haluzík, M., Al-Sofiani, M. E., Cheng, A. Y. Y., Lauand, F., Melas-Melt, L., & Rosenstock, J. (2024). Time-in-range derived from self-measured blood glucose in people with type 2 diabetes advancing to iGlarLixi: A participant-level pooled analysis of three phase 3 LixiLan randomized controlled trials. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.15811

Readers over time

‘24‘2506121824

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

100%

Readers' Discipline

Tooltip

Medicine and Dentistry 3

100%

Save time finding and organizing research with Mendeley

Sign up for free
0